ZeroHour

Search: “ics-advisory”

30 stories

Smart search ranks by meaning as well as keywords (one row per story, last 45 days).

[Control Systems] Inductive Automation security advisory (AV26-892)

Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.

The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.

Canadian Centre for Cyber Security · 8d agoAdvisory

ICS Operators Warned of AI-Driven Attacks on Siemens PLCs

A US government advisory warns attackers are using AI-generated exploitation scripts against internet-exposed Siemens S7 Series PLCs.

A US government advisory warns ICS operators that attackers are targeting exposed Siemens S7 Series PLCs using AI-generated exploitation scripts. The use of AI to automate exploit development and delivery marks an escalation in threats to industrial control systems. Operators of exposed PLCs are warned to harden their environments as AI-assisted tooling lowers the barrier for adversaries.

Infosecurity Magazine · 27d agoExploit / PoC in the wild

CISA Calls for More Guidance, Less Spin, as Cyber Outages Escalate

CISA and partners issue a joint advisory pressing organizations toward transparent breach notification and incident response as cyber outages escalate.

Dark Reading reports on a new joint government advisory led by CISA that signals a regulatory shift. The advisory presses organizations to adopt more transparent breach notification protocols and incident response practices. The guidance comes as cyber outages escalate and reflects growing government expectation of disclosure over spin.

Dark Reading · 5d agoPolicy & legal1

[Control Systems] Siemens security advisory (AV26-890)

Canada's Cyber Centre relayed a Siemens advisory affecting Reyrolle 7SR5, Teamcenter, Siveillance Control, Desigo CC and other products.

Advisory AV26-890, dated September 8, 2026, flags Siemens vulnerabilities in Reyrolle 7SR5 (versions prior to V2.70), Teamcenter, Siveillance Control, SIMATIC AX Runtime, Desigo CC, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT across multiple versions and models. The Cyber Centre encourages users and administrators to review the Siemens advisory and apply available updates. No specific CVEs or exploitation details are provided in the relayed advisory.

Canadian Centre for Cyber Security · 8d agoAdvisory

[Control Systems] National Instruments security advisory (AV26-914)

Canada's Cyber Centre relayed a National Instruments advisory covering improper access control and cleartext sensitive-information flaws in NI SystemLink and SystemLink Server.

Advisory AV26-914, dated September 11, 2026, notes that NI SystemLink and SystemLink Server prior to or equal to 2026 Q3 Patch 1 are affected by improper access controls and storage of sensitive information in cleartext. The Canadian Centre for Cyber Security urges users and administrators to review the vendor's links and apply available security updates.

Canadian Centre for Cyber Security · 5d agoAdvisory2

Water sector example added to the NCSC’s Secure connectivity principles

NCSC UK adds a water sector example to its Secure Connectivity Principles, the first ICS community-authored content on its site.

The UK NCSC has added a water sector example to its Secure Connectivity Principles guidance. It is the first content authored by the Industrial Control System Community of Interest to appear on ncsc.gov.uk. The guidance helps ICS operators apply secure connectivity practices.

NCSC UK · Aug 11, 2026Advisory

Cisco security advisory (AV26-876)

Canada's Cyber Centre relayed Cisco advisories covering a Nexus 9000 Silicon One RCE, IOS XR hardening, and denial-of-service flaws across IP phone lines.

The Canadian Centre for Cyber Security advisory AV26-876 lists Cisco vulnerabilities affecting IOS XR, Nexus 9000 Series switches, and several IP phone series. Included are a Nexus 9000 Silicon One remote code execution vulnerability, a September 2026 IOS XR security hardening release, and SIP software denial-of-service flaws in Desk Phone 9800, IP Phone 7800/8800, and Video Phone 8875. The Cyber Centre urges users and administrators to review the Cisco advisories and apply updates as they become available. No active exploitation is reported in the advisory.

Canadian Centre for Cyber Security · 13d agoAdvisory

Cisco Advance Notification for Publication of August 19, 2026, Security Advisories

Cisco PSIRT's advance notice previews August 19, 2026 advisories including Critical CVSS 10.0 hardening releases for Crosswork and Secure Workload.

Cisco PSIRT issued an advance notification for security advisories published August 19, 2026. The batch includes Critical-rated (CVSS 10.0) hardening releases for Cisco Crosswork and Cisco Secure Workload, a High-severity blind XML External Entity injection in BroadWorks (CVE-2026-20320, CVSS 7.5), a Medium SQL injection in Unified Intelligence Center (CVE-2026-20327, CVSS 6.5), and a RoomOS stack overflow. Full details and fixes follow in the individual advisories.

[Control Systems] National Instruments security advisory (AV26-856)

Canada's Cyber Centre relayed National Instruments advisories for memory corruption, out-of-bounds read, and out-of-bounds write flaws in LabVIEW versions.

The Canadian Centre for Cyber Security published control systems advisory AV26-856 covering National Instruments LabVIEW. Affected versions include releases before 23.0.0, 23.3.10, 24.3.7, 25.3.5, and 26.3.1. The flaws include memory corruption, an integer conversion out-of-bounds read, and an integer overflow out-of-bounds write. Users and administrators are urged to review the links and apply NI security updates.

Canadian Centre for Cyber Security · 19d agoAdvisory

IBM security advisory (AV26-862)

Canada's Cyber Centre relayed an IBM advisory disclosing vulnerabilities across SPSS, MQ, Maximo, Instana, Concert and other IBM products.

The Canadian Centre for Cyber Security (AV26-862) published an IBM security advisory dated August 31, 2026, noting vulnerabilities affecting multiple IBM products as of August 28, 2026. Affected products include SPSS Collaboration and Deployment Services, IBM MQ Agent, Maximo Application Suite Monitor Component, Observability with Instana agent, Financial Transaction Manager for Red Hat OpenShift, Engineering Test Management, Control Center, Concert Software and Tivoli System Automation. No CVE identifiers, CVSS scores or exploitation details are provided in the relayed text.

Canadian Centre for Cyber Security · 16d agoAdvisory

ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws

September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.

Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

Communicating Under Pressure: Best Practices for Service Providers

CISA, FBI, and international partners issued guidance on crisis communications for service providers during IT and OT outages, emphasizing clarity, transparency, and backup channels.

CISA, the FBI, and international partners published guidance on planning and executing clear, timely, audience-appropriate communications during IT and OT service outages, whether caused by cyber threat actors, human error, or natural hazards. The guidance stresses clarity, accountability, and transparency, and warns that outages at one organization can cascade across interconnected systems. It recommends critical infrastructure owners assume telecommunications may be unreliable and integrate backup communication methods into crisis plans, and points to CISA's CI Fortify initiative for OT isolation and recovery resources.

CISA Advisories · 14d agoAdvisory

Mitsubishi Electric CNC Series (Update A)

CISA's updated ICS advisory details CVE-2025-2399, an out-of-bounds read in Mitsubishi Electric CNC series that lets a remote attacker cause a denial-of-service condition.

CISA released Update A of ICS advisory ICSA-26-078-05 covering Mitsubishi Electric CNC series controllers. The vulnerability CVE-2025-2399 is an out-of-bounds read that a remote attacker can exploit to trigger a denial-of-service condition. Affected products include M800VW, M800VS, M80V, M80VW, M800W, M800S and M80 series controllers up to specified firmware revisions. No exploitation is reported in the advisory.

CISA Advisories · 20d agoAdvisoryCVE-2025-2399

Frequently asked questions about the active threat to Siemens S7 Series PLCs

US government agencies warn that unattributed actors using AI-generated exploit scripts are targeting internet-exposed Siemens S7 PLCs in critical infrastructure.

A joint advisory from multiple U.S. government agencies warns that threat actors are exploiting known weaknesses and unnecessary internet exposure of Siemens S7 Series PLCs for reconnaissance and possible pre-positioning for future disruptive attacks. The attackers use AI to generate and refine exploit scripts faster than manual development would allow, lowering the technical bar for ICS attacks. There is no single patch, so defenders must reduce internet exposure and improve monitoring of ICS environments.

Tenable Blog · 27d agoExploit / PoC in the wild

Managing the cyber risk of agentic AI

UK NCSC guidance recommends safeguards, sandboxing, and active oversight to manage cyber risks of autonomous agentic AI systems.

The UK National Cyber Security Centre published guidance on managing the cyber risk of agentic AI systems. It recommends safeguards, sandboxing, and active human oversight to limit unintended autonomous activity while realizing the benefits of these systems. The publication is official national guidance for organizations deploying agentic AI.

NCSC UK · 27d agoAdvisory

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

ISC BIND security advisory (AV26-931)

Canadian Cyber Centre relays ISC advisory on vulnerabilities affecting multiple BIND 9 branches; administrators should review the matrix and apply updates.

On September 16, 2026, the Canadian Centre for Cyber Security (AV26-931) relayed ISC's advisory on vulnerabilities affecting ISC BIND 9 versions prior to or equal to 9.18.50, 9.20.27, and 9.21.25, including their -S1 variants. No specific CVE identifiers or exploitation details are provided in the bulletin. Administrators are directed to ISC's BIND 9 Software Vulnerability Matrix and encouraged to apply updates as they become available.

Canadian Centre for Cyber Security · 11h agoAdvisory

Poster: Towards Selecting Threat Appropriate Industrial Intrusion Detection Systems

Poster proposes counter-threat-intelligence-based detector selection for industrial control systems, showing IDS performance varies strongly by attack scenario.

The poster proposes a counter-threat intelligence sharing mechanism to select appropriate intrusion detection systems for the current threat situation in industrial control system environments. Attack-level performance evaluations of various IDSs show detection performance varies depending on the attack scenario. The results emphasize the benefit of dynamically matching detectors to evolving ICS threats.

arXiv cs.CR · 5d agoResearch

[Control systems] Schneider Electric security advisory (AV26-912)

Canada's Cyber Centre relays a Schneider Electric advisory covering multiple vulnerabilities in EcoStruxure IT Data Center Expert and PowerLogic T300, urging users to apply updates.

The Canadian Centre for Cyber Security issued advisory AV26-912 noting that as of September 9, 2026 Schneider Electric is affected by vulnerabilities in EcoStruxure IT Data Center Expert versions 9.1.2 and prior, and PowerLogic T300 versions 2.9.8-5620 and prior. The issues include an improper neutralization of special elements used in an OS command on the PowerLogic T300. The advisory recommends reviewing vendor notifications, performing suggested mitigations, and applying necessary updates.

Canadian Centre for Cyber Security · 5d agoAdvisory

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

NYS DFS Issues New Cybersecurity Guidance on Risk Assessments for Financial Services Entities

New York DFS issued cybersecurity guidance defining expectations for risk assessments that regulated financial services entities must conduct.

On September 10, 2026, NYS DFS Acting Superintendent Kaitlin Asrow issued new cybersecurity guidance on conducting risk assessments sufficient to inform cybersecurity programs. The guidance covers scope, frequency, and the role of assessments for DFS-regulated financial services entities. It does not describe any incident or vulnerability, but sets regulatory compliance expectations under DFS cybersecurity rules.

DataBreaches.net · 4d agoPolicy & legal

[Control systems] Advantech security advisory (AV26-907)

Canada's Cyber Centre flagged vulnerabilities in the Advantech WISE-6610 industrial gateway and urged users to apply available updates.

Advisory AV26-907, dated September 10, 2026, states that multiple versions and models of the Advantech WISE-6610 industrial gateway are affected by vulnerabilities. The Canadian Centre for Cyber Security encourages users and administrators to review the provided links and apply updates as they become available. No CVE identifiers or exploitation details were included in the announcement.

Canadian Centre for Cyber Security · 6d agoAdvisory

WebPros security advisory (AV26-866)

Canada's Cyber Centre relays a WebPros advisory for CVE-2026-67394, a Plesk privilege escalation flaw to root, fixed in 18.0.79.9 and 18.0.80.5.

The Canadian Centre for Cyber Security issued alert AV26-866 relaying WebPros' security advisory for Plesk. CVE-2026-67394 allows privilege escalation to root and affects Plesk versions prior to 18.0.79.9 and 18.0.80.5. Administrators are encouraged to review the advisory and apply the available updates.

JetBrains security advisory (AV26-891)

Canada's Cyber Centre relayed a JetBrains advisory covering vulnerabilities in GoLand, Hub, IntelliJ IDEA and YouTrack.

Advisory AV26-891, dated September 8, 2026, notes JetBrains vulnerabilities affecting GoLand prior to 2026.2.2.1, Hub prior to 2026.2.52442, IntelliJ IDEA prior to 2026.2.2, and multiple YouTrack versions. Users and administrators are encouraged to review JetBrains' advisory and apply any necessary updates. No specific CVEs or exploitation details are provided in the relayed advisory.

Canadian Centre for Cyber Security · 8d agoAdvisory

Cisco Identity Services Engine Cross-Site Scripting Vulnerability

Cisco patched a reflected XSS in the ISE management interface allowing unauthenticated attackers to execute script via crafted links.

A reflected cross-site scripting vulnerability in the web-based management interface of Cisco Identity Services Engine lets an unauthenticated remote attacker execute arbitrary script in the context of the interface. Exploitation requires persuading a user to click a crafted link due to improper input validation. Cisco has released software updates.

Cisco Security Advisoriesupdated · 49m agofirst · 15h agoAdvisory 16 sources

"Chilling" warning or overreaction? AI bioweapons report divides experts

Science article examines expert disagreement over whether a report on AI-enabled bioweapons risks is a chilling warning or an overreaction.

A Science.org article, shared on Hacker News with 20 points and 2 comments, covers expert divisions over an AI bioweapons report and whether its warnings are justified or exaggerated. The discussion reflects ongoing debate in the AI safety and biosecurity community about assessing AI's role in biological threat enhancement. Minimal detail is available from the item itself.

Jenkins security advisory (AV26-877)

Canada's Cyber Centre relayed a Jenkins advisory (AV26-877) covering core and numerous plugin vulnerabilities fixed in 2.568.3/2.580.

The Canadian Centre for Cyber Security published advisory AV26-877 for the Jenkins security advisory dated September 2, 2026. Affected products include Jenkins releases other than 2.568.3 and 2.580, plus plugins such as GitLab, LDAP, Microsoft Entra ID, SAML, Script Security, Pipeline Build Step, and others. Administrators are encouraged to review the linked advisory and apply necessary updates.

Canadian Centre for Cyber Security · 13d agoAdvisory