ZeroHour

Search: “medium-voltage”

30 stories

Smart search ranks by meaning as well as keywords (one row per story, last 45 days).

Powering AI is an architecture problem

Sponsored analysis argues AI data centers need medium-voltage, inline power architecture after Virginia grid faults knocked over 3GW of load offline.

A sponsored MIT Technology Review piece recounts a July 22, 2026 transmission fault in Ashburn, Virginia that shed more than 3 GW of data center load, and a 2024 incident where one failed surge arrester dropped about 60 facilities and 1,500 MW. It argues legacy UPS-based power stacks fail at AI scale because campuses can swing 70% of load in milliseconds and trip offline during grid disturbances. The proposed fix moves protection to medium voltage (13.8 kV and above) in inline enclosures near substations, improving density, permitting timelines, and backup power economics. A full-scale system tested at the DOE National Laboratory of the Rockies cleared ERCOT large-load ride-through requirements.

MIT Technology Review · AI · 6d agoAI industry1

Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

Compact ResNet detects electrical faults in 400 Hz aircraft power systems with 95.87 percent accuracy after deployment on Xilinx Zynq MPSoC.

The study targets multiclass fault and power quality disturbance detection in 400 Hz aerospace networks using a high-fidelity simulation model inspired by the Boeing 787 electrical architecture, covering 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two 73,500-sample datasets are built from 1D waveforms and STFT time-frequency representations, augmented with domain randomization and class-specific GANs, and the time-series dataset is released via IEEE DataPort. A compact ResNet with 175,685 parameters achieved 96.94 percent software test accuracy, and 95.87 percent after 8-bit quantization on a Xilinx Zynq UltraScale Plus ZCU102 with 6.90 ms mean accelerator latency per record.

arXiv cs.AI / cs.LG / cs.CL · 7d agoAI research

PHAT: PHotonic Accelerator for TFHE

PHAT photonic accelerator using optically addressed phase-change memory speeds TFHE bootstrapping FFTs 2.14x-5.10x over the prior ASIC accelerator.

Researchers propose PHAT, an electro-photonic accelerator for TFHE fully homomorphic encryption built on optically addressed phase-change memory (OPCM) processing-in-memory. The architecture adds OPCM-based FFT units, a twiddle-stationary dataflow, and a scheduling mechanism to maximize FFT utilization for TFHE bootstrapping. It achieves 2.14x-5.10x speedups across four real-world TFHE workloads versus the state-of-the-art ASIC accelerator, improving feasibility of privacy-preserving computation in the cloud.

arXiv cs.CR · 6d agoResearch

Mitsubishi Electric Multiple FA Products (Update D)

CISA warns Mitsubishi Electric CC-Link IE TSN remote I/O modules are vulnerable to denial-of-service via crafted UDP packets (CVE-2025-3511).

CISA published Update D of advisory ICSA-25-128-03 covering Mitsubishi Electric factory automation products. Affected products include CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, and NZ2GN2S1-32DT at firmware version 09 or earlier (CVE-2025-3511). A remote attacker can send a specially crafted UDP packet to cause denial-of-service conditions, timeout errors, or communication delays on the affected products.

CISA Advisories · 20d agoAdvisoryCVE-2025-3511

A battery storage cyberattack would look exactly like a badly tuned controller

Risk modeling suggests a few hundred compromised grid-scale batteries dispatched through cloud optimizers could trigger blackouts in Texas or Great Britain.

Centrii analysis estimates 1,500 compromised one-megawatt units (5.4% of ERCOT's ~28 GW fleet) or 400 units (about 29% of Great Britain's ~1,400-unit fleet) could destabilize the grids, with modeled damage of $12-65 billion in Texas and a national blackout costing £2-10 billion in Britain. The study puts the probability of a major attack affecting at least one million people by 2031 at 92.1%, dropping to 61.4% with IEC 62443 certification and quarterly drills, based on 10,000 Monte Carlo runs. Because hostile battery swings are phased like legitimate frequency response, control rooms would see nothing unusual; Centrii proposes hunting for a reverse-governor signature where inverter output feeds oscillations. Spain's April 2025 blackout took an expert panel until March 2026 to rule out cyberattack, partly because key plants had no recordings.

Help Net Security · 15d agoResearch

VU#431093: TCG TPM 2.0 reference code found vulnerable to information leakage and timing side-channel attacks

CERT/CC discloses two TPM 2.0 reference code flaws allowing RSA key decryption and forged TPM attestations via crafted commands.

CERT/CC published VU#431093 covering two vulnerabilities in the TCG TPM 2.0 reference implementation: CVE-2026-6726 (information leakage via falsified TPM keys) and CVE-2026-6727 (timing side-channel in RSA OAEP decryption). An attacker with privileged access to a TPM command interface could send crafted TPM commands to decrypt ciphertexts for affected TPM-managed RSA keys, including the RSA Endorsement Key, or obtain credentials enabling forged TPM 2.0 attestations. Remediation is tracked in TCGVRT010 and TCGVRT0011.

Wicked Problem, Parsimonious Solution: Securing Electric Vehicle Charging Station Software

Position paper proposes hierarchical software quality assurance to characterize and secure EV charging station software attack surfaces.

The authors argue that charging station supply-equipment software is a largely unprotected and poorly characterized attack surface in EV charging infrastructure. They advocate applying hierarchical software quality assurance (HSQA) to this specialized software, spanning from individual vulnerabilities such as CVEs to high-level characteristics like the CIA Triad. HSQA embeds quality and security considerations across the entire software development lifecycle to assess and improve charging station software security.

arXiv cs.CR · 7d agoResearch

[Control systems] Schneider Electric security advisory (AV26-912)

Canada's Cyber Centre relays a Schneider Electric advisory covering multiple vulnerabilities in EcoStruxure IT Data Center Expert and PowerLogic T300, urging users to apply updates.

The Canadian Centre for Cyber Security issued advisory AV26-912 noting that as of September 9, 2026 Schneider Electric is affected by vulnerabilities in EcoStruxure IT Data Center Expert versions 9.1.2 and prior, and PowerLogic T300 versions 2.9.8-5620 and prior. The issues include an improper neutralization of special elements used in an OS command on the PowerLogic T300. The advisory recommends reviewing vendor notifications, performing suggested mitigations, and applying necessary updates.

Canadian Centre for Cyber Security · 5d agoAdvisory

Mitsubishi Electric CNC Series (Update A)

CISA's updated ICS advisory details CVE-2025-2399, an out-of-bounds read in Mitsubishi Electric CNC series that lets a remote attacker cause a denial-of-service condition.

CISA released Update A of ICS advisory ICSA-26-078-05 covering Mitsubishi Electric CNC series controllers. The vulnerability CVE-2025-2399 is an out-of-bounds read that a remote attacker can exploit to trigger a denial-of-service condition. Affected products include M800VW, M800VS, M80V, M80VW, M800W, M800S and M80 series controllers up to specified firmware revisions. No exploitation is reported in the advisory.

CISA Advisories · 20d agoAdvisoryCVE-2025-2399

[Control systems] Schneider Electric security advisory (AV26-871)

Canada's Cyber Centre relayed Schneider Electric advisories for vulnerabilities in NetBotz 5-750/755 (5.5.2 and prior) and PowerChute Serial Shutdown (1.5 and prior).

The Canadian Centre for Cyber Security issued control-systems advisory AV26-871 noting Schneider Electric products affected by vulnerabilities as of September 1, 2026. Affected products include NetBotz 5-750/755 versions 5.5.2 and prior, and PowerChute Serial Shutdown versions 1.5 and prior, the latter with an improper restriction of excessive authentication attempts flaw. Administrators are urged to review Schneider Electric's security notifications and apply the suggested mitigations and updates.

Canadian Centre for Cyber Security · 14d agoAdvisory

New Guidance Helps Businesses Verify Quantum-Safe Hardware Claims

TCG issued guidance to help businesses verify that trusted platform modules genuinely meet quantum-safe requirements.

The Trusted Computing Group (TCG) published new guidance aimed at proving that trusted platform modules (TPMs) genuinely satisfy essential quantum-safe requirements. The document gives businesses a way to validate vendor claims about post-quantum readiness in hardware security rather than trusting marketing assertions. This is a guidance publication, not an incident or vulnerability disclosure.

Infosecurity Magazine · 23d agoAdvisory

[Control Systems] Inductive Automation security advisory (AV26-892)

Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.

The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.

Canadian Centre for Cyber Security · 8d agoAdvisory

A Deep Dive Into Attempted Exploitation of CVE-2023

Mirai-like botnet scans exploit TP-Link EOL router flaw CVE-2023-33538 after CISA KEV addition, though observed exploit code is flawed.

Unit 42 observed large-scale automated scans attempting to exploit CVE-2023-33538 in end-of-life TP-Link TL-WR940N, TL-WR740N and TL-WR841N routers after CISA added the flaw to its KEV catalog in June 2025. HTTP GET requests inject commands via the ssid1 parameter at the /userRpm/WlanNetworkRpm endpoint to download and execute an arm7 ELF binary, a Mirai variant related to the Condi IoT botnet. Firmware emulation and reverse engineering showed the observed exploits are flawed and would fail, but the underlying vulnerability is real and successful exploitation requires authentication to the router's web interface. TP-Link confirmed the devices are end-of-life with no patches available and recommends replacing units and eliminating default credentials.

Palo Alto Unit 42 · 28d agoExploit / PoC in the wildCVE-2023-335381

Large Language Models for HVAC Operations in Building Energy Systems: A Critical Review of Methods, Applications, and Deployment Readiness

Systematic review of 66 studies finds LLMs for HVAC operations are mostly research-stage, with no ready-now deployment and only four pilot-level studies.

A critical review of 66 peer-reviewed studies from 2023 to March 2026 examines LLMs for HVAC operations in building energy systems. Only four studies reach pilot-level evidence, none reports sustained operational deployment, and 63 of 66 are research-only. Conventional ML, MPC, and RL remain dominant for high-frequency control and short-horizon forecasting, and the evidence supports LLMs primarily as semantic and workflow layers rather than autonomous controllers.

arXiv cs.AI / cs.LG / cs.CL · 12d agoAI research

Perturbation Probing: A New Diagnostic for the Fragility of LLM Safety

Unit 42 research shows LLM safety refusals concentrate in a thin neural layer, motivating external, multi-layered AI security controls.

Palo Alto Networks Unit 42 introduces Perturbation Probing, a diagnostic technique for measuring the fragility of LLM safety mechanisms. The research finds that safety refusal behavior is localized within a thin neural layer, implying small perturbations can undermine built-in refusals. The authors argue this motivates external, multi-layered security defenses on top of model-internal safety training.

Palo Alto Unit 42 · 19d agoAI safety & security

Domain-Specific Hallucination Detection in Large Language Models

A multi-signal pipeline detects LLM hallucinations, reaching F1 0.915 on HaluEval and cutting Qwen2.5-0.5B hallucination rates from 85.5% to 37.7% via DPO.

The paper presents a hallucination detection pipeline combining fine-tuned DeBERTa-v3 classification, Monte Carlo Dropout uncertainty, and temperature-scaled calibration. It achieves F1 0.915 and AUROC 0.977 on general-domain HaluEval tasks, with MC Dropout inference raising accuracy to 93.2%. Applying DPO to a Qwen2.5-0.5B generator reduces its hallucination rate from 85.5% to 37.7%, while cross-domain evaluation shows poor general-domain transfer to SciFact (F1 0.52) and PubMedBERT fine-tuning as the strongest adaptation (F1 0.63).

arXiv cs.AI / cs.LG / cs.CL · 6d agoAI research1

Injected and Leaked: Actively Inducing Side-Channel Leakage Using Electromagnetic Injection and Hardware Nonlinearity

Researchers introduce InjectEave, using electromagnetic injection and hardware nonlinearity to induce side-channel leakage and eavesdrop on headphone audio from 30 meters.

An arXiv paper shows electromagnetic injection can actively amplify side-channel leakage: nonlinear hardware such as amplifiers, ADCs, and power converters modulates secret electrical signals onto an injected EM carrier, upconverting low-frequency secrets into measurable EM emissions. By tuning injection frequency and amplitude, an adversary can shape the effective spectrum and entropy of the resulting leakage. The InjectEave attack demonstrated eavesdropping on wired and wireless headphone audio from up to 30 meters and in through-wall scenarios using accessible RF equipment, plus leakage of smart home device power consumption and analog sensor inputs. Case studies show closed-loop eavesdropping and manipulation of landline phone conversations, and the paper discusses mitigations.

arXiv cs.CR · 12d agoResearch

How an Emerging Industrial Protocol Family Could Put OT at Risk

New research shows unprotected Time-Sensitive Networking industrial protocols could let attackers disrupt or manipulate physical processes in OT environments.

Research covered by Dark Reading examines an emerging family of industrial protocols based on Time-Sensitive Networking (TSN) and finds that unprotected implementations could be attacked to disrupt or manipulate physical processes. The findings highlight growing OT risk as these protocols proliferate in industrial deployments; no confirmed exploitation is reported.

Dark Reading · 26d agoResearch

ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws

September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.

Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.

Heap overflow in kernel driver due to missing size validation

Fortinet fixes a CVSS 7.3 heap overflow in the FortiClient Windows kernel driver enabling code execution via crafted DNS responses.

Fortinet PSIRT advisory FG-IR-26-156, revised 2026-08-12, describes a heap-based buffer overflow (CWE-120, buffer copy without checking input size) in the FortiClient Windows kernel driver, scored CVSSv3 7.3. An unauthenticated attacker positioned to alter or craft DNS responses for a targeted host could execute arbitrary code via malicious packets. No CVE identifier or exploitation status is provided in the advisory text, so administrators should check the full bulletin for affected versions and fixed releases.

Fortinet PSIRT · Aug 12, 2026Advisory

[Control Systems] Siemens security advisory (AV26-864)

Siemens fixed a vulnerability in Element maps-ng V47-V49 (SSA-682041); Canada's Cyber Centre urges administrators to apply the updated releases.

Siemens advisory SSA-682041 addresses a vulnerability affecting Element maps-ng V47 prior to V47.12.3, V48 prior to V48.11.3, and V49 prior to V49.16.1. Canada's Cyber Centre republished the notice (AV26-864) encouraging users and administrators to review the vendor links and apply the necessary updates. No CVSS score or exploitation details were provided in the bulletin.

Canadian Centre for Cyber Security · 16d agoAdvisory

Russian-Linked Hackers Accessed Polish Power Plant OT Network Through Private APN, Says CERT.PL

CERT.PL disclosed that Russian-linked hackers accessed a Polish combined heat and power plant's OT network through a private APN in 2025.

Poland's CERT (CERT.PL) released details of a 2025 attack on a Polish combined heat and power plant. Russian-linked hackers accessed the plant's OT network through a private APN. The disclosure adds to a series of intrusions against Polish critical infrastructure attributed to Russian-linked actors.

Infosecurity Magazine · Aug 12, 2026Threat actor in the wild

White House bans foreign-made equipment for power generation over cyber backdoor concerns

Trump executive order bans acquisition of foreign-made bulk-power system equipment over cyber backdoor and supply-chain concerns for US electricity infrastructure.

The White House issued an executive order declaring foreign-made bulk-power system electric equipment an "unusual and extraordinary threat," banning its acquisition or installation in the US. The order covers technology managing transmission lines rated at 69,000 volts or higher, substations, control rooms, power generating stations, reactors, and associated remotely accessible software and firmware. It follows recent cyberattacks on water utilities in at least 12 states, malicious activity targeting over 100 internet-exposed water and wastewater systems, and an NSA/FBI advisory on an AI-powered threat to operational technology. The Defense, Commerce, and Energy Departments have 120 days to create rules, identify countries warranting scrutiny, and inventory at-risk equipment.

The Record · 20d agoPolicy & legal

Decomposition-Guided Diffusion Language Models for Inertial Confinement Fusion Prediction

ICF-DLM, the first language-model-based inertial confinement fusion predictor, cuts peak-timing error from 11.6 to 9.2 steps versus LLaMA-3-8B.

Each National Ignition Facility shot costs roughly one million dollars, motivating accurate AI surrogates for predicting 512-step neutron-rate waveforms from laser pulses and target parameters. ICF-DLM combines physics-typed decomposition into yield, peak timing, and local waveform; bidirectional denoising that defers commitment to peak location; and a physics-driven PPO reward. On ICFBench (50,000 simulations plus 232 experimental shots) it outperforms a matched autoregressive LLaMA-3-8B, classical sequence models, and LLM-based time-series predictors.

arXiv cs.AI / cs.LG / cs.CL · 9d agoAI research

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

Bipartisan Senate bill aims to prepare energy sector for Q

Bipartisan Senate bill would direct FERC to factor quantum computing threats and post-quantum cryptography into US electric grid cybersecurity reliability standards.

The Quantum Grid Utility Assurance and Resilient Defense (Quantum-GUARD) Act, introduced by Senators Mike Rounds and Chris Coons, would require FERC to consider quantum computing threats when reviewing electric reliability standards and to explore post-quantum cryptography use in both IT and OT systems, plus a technical sandbox to study quantum impacts. It aligns with NIST's post-quantum algorithm work, and a June executive order moved the federal PQC migration deadline from 2035 to 2030. Industry experts noted the hard part is upgrading infrastructure such as SCADA communications and software update integrity ahead of those deadlines.

CyberScoop · 23d agoPolicy & legal

New TCG guidance gives buyers a way to test PQC-ready TPM claims

Trusted Computing Group published PTP 1.07-based requirements defining PQC-ready and PQC-upgradable TPM designations to guide buyers assessing quantum-safe hardware.

The Trusted Computing Group published requirements establishing PTP 1.07, based on TPM 2.0 Library Specification Version 1.85, as the baseline for a 'TCG PQC-ready TPM', and defined a second designation, 'TCG PQC-upgradable TPM', for chips that can be upgraded to that support. The guidance lets buyers request vendor evidence that TPMs meet end-to-end post-quantum requirements for identities, attestation, and hardware-anchored trust rather than single-algorithm compliance. TCG also announced plans to extend its certification programs to certify TPMs meeting PTP 1.07, noting that 90% of businesses still lack a formal PQC roadmap.

Help Net Security · 23d agoTools

WireGuard-Linux Stack-Based Buffer Overflow in lsiio (Linux IIO Userspace Tool) Due to Unbounded fscanf

The Linux IIO userspace tool lsiio has a stack buffer overflow in find_type_by_name() caused by unbounded fscanf reads of oversized filesystem-backed attribute values.

A stack-based buffer overflow exists in the Linux Industrial I/O (IIO) userspace utility lsiio. In the find_type_by_name() function, the program reads an unbounded string from a filesystem-backed attribute into a fixed-size stack buffer using fscanf("%s", ...). A crafted or oversized attribute value causes a write beyond the bounds of the destination buffer. Despite the title's reference to WireGuard-Linux, the flaw described is in the IIO lsiio utility.

Full Disclosure · 13d agoVulnerability