A joint advisory from CISA, NSA and FBI alleges China-based AI companies including DeepSeek, Moonshot AI, Alibaba, MiniMax, StepFun and Z.AI harvested billions of tokens across millions of exchanges from Claude, GPT, Gemini and Grok variants since late 2024. Operators allegedly used API proxy 'transfer stations', account pools, bulk premium subscriptions and prompt injection or jailbreak-style requests to force models to reveal chain-of-thought reasoning. DeepSeek's R1 and V3 and Moonshot's Kimi-K2 and Kimi-K3 models reportedly benefited from the extracted data. CISA urged providers to add identity checks, monitor subscription-to-usage ratios, rate limit, and share infrastructure signals with cloud platforms.
Schneider Electric SCADAPack x70 Products
CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.
CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.
Orthanc DICOM Server
CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.
CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.
AVEVA Pipeline Integrity Monitor
CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.
CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.
Inductive Automation Ignition
CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.
CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.
Tycon Systems TPDIN-Monitor-WEB3
CISA reports three flaws (hard-coded credentials, CSRF, missing authorization) in Tycon TPDIN-Monitor-WEB3 <=2.2.9 enabling MitM, credential theft, or device resets.
CISA published ICSA-26-246-08 for Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior, covering CVE-2026-77847 (use of hard-coded credentials, CWE-798), CVE-2026-82712 (CSRF, CWE-352), and CVE-2026-82684 (missing authorization, CWE-862). Exploitation could enable man-in-the-middle attacks, factory resets, credential wiping, or extraction of system credentials, configurations, and flash contents; the CSRF issue scores CVSS 8.8. No public exploitation has been reported; CISA recommends isolating devices from business networks.
Siemens Teamcenter
Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).
CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.