ZeroHour

Search: “Secure Connect Gateway”

366 stories

Dell Secure Connect Gateway Vulnerabilities Allow Hackers to Gain Unauthorized Access

Dell patches three critical flaws (CVSS up to 9.8) in Secure Connect Gateway 5.0 enabling admin token replay, unauthenticated RCE, and root escalation.

Dell disclosed three critical vulnerabilities in Secure Connect Gateway 5.0 appliance and application deployments. CVE-2026-80172 (CVSS 9.8) lets unauthenticated attackers replay captured requests, which lack nonce validation and time limits, to repeatedly mint administrator access and refresh tokens. CVE-2026-61410 (9.4) is a missing-authorization flaw enabling unauthenticated remote command execution, and CVE-2026-80238 (9.3) is an exposed Docker socket allowing local privilege escalation to root and container escape. Fixes ship in appliance 5.36.00.16 and application 5.36.00.00.

Dell Secure Connect Gateway Critical Flaws Allow Unauthenticated Remote Code Execution and Admin Access

Dell patched three critical Secure Connect Gateway flaws (CVE-2026-80172 up to CVSS 9.8) enabling unauthenticated admin access, remote code execution, and host takeover.

Dell Security Advisory DSA-2026-382 fixes three critical vulnerabilities in Secure Connect Gateway (SCG) 5.0, affecting appliances earlier than 5.36.00.16 and applications earlier than 5.36.00.00. CVE-2026-80172 (CVSS 9.8) allows unauthenticated replay of captured requests to obtain ADMIN access due to missing nonce and time validation; CVE-2026-61410 (9.4) enables unauthenticated command execution via missing authorization; CVE-2026-80238 (9.3) involves an exposed Docker socket allowing root access and container escape. Dell urges immediate upgrades and recommends restricting management interfaces to trusted networks and rotating credentials if compromise is suspected.

CISA Warns Water Utilities: Find Your Exposed PLCs Before Attackers Do

CISA urged water utilities to secure internet-exposed PLCs after July 2026 attacks compromised over 100 US water and wastewater systems, suspected Iran-linked.

CISA's exposure-reduction guidance, published August 21, follows July 2026 attacks in which threat actors remotely accessed PLCs connected directly through cellular modems, changed device IP addresses and passwords, and in some cases disabled alarms and shutdown processes without notifying operators. Iran is the suspected actor, though officials stopped short of formal attribution. CISA recommends routing remote access through centrally managed secure gateways, phishing-resistant MFA, unique credentials, and external scanning of industrial protocols such as Modbus, EtherNet/IP, DNP3, BACnet and OPC UA.

Security Affairs · 20d agoExploit / PoC in the wild