ZeroHour

CVE-2025-67038

KEVmoderate

Unauthenticated Root Command Injection in Lantronix EDS5000 Device Servers

CISA: Lantronix EDS5000 Code Injection Vulnerability

CVSS 4.0
9.3 critical
EPSS
19%p97
Published
()
KEV added
AI analysis

CVE-2025-67038 is an OS command injection flaw (CWE-78) in the HTTP RPC module of Lantronix EDS5000 series device servers, with firmware 2.1.0.0R3 confirmed affected. When a login attempt fails, the module writes a log entry by building a shell command that directly concatenates the username from the request without any sanitization, so an attacker who sends a crafted username in an authentication request gets their commands appended to it. Because the log-writing command runs as root, an unauthenticated, network-reachable attacker gains full command execution with the highest privileges on the device. Any organization running network-exposed Lantronix EDS5000 device/console servers (EDS5008, EDS5016, EDS5032, and the G526/G527-series variants) is affected. CISA added the flaw to its Known Exploited Vulnerabilities catalog on 2026-06-23 and reports it is being actively exploited; the EPSS score of 19.3% (97th percentile) reflects a high near-term exploitation risk.

What to do: Upgrade EDS5000-series firmware to a patched release per Lantronix's guidance, since no fixed version is specified in the available data and 2.1.0.0R3 is confirmed vulnerable; if patching is not yet possible, restrict HTTP access to the device's management interface at the network level. Federal agencies must apply vendor mitigations per CISA BOD 26-04 requirements following the 2026-06-23 KEV listing. Check device logs and configs for signs of compromise, since successful injection yields root-level command execution.

Affected
lantronix eds5008 firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix eds5016 firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix eds5032 firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g526gp12s firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g526gp17s firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g526gp1cs firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g526gp1asg firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g526gp1as firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g527gp22s firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g527gp27s firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g527gp2as firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
lantronix g527gp2asg firmwareEDS5000-series firmware; 2.1.0.0R3 confirmed affected, no fixed version specified in available data
Estimated exposure
moderate≈ several thousand internet-exposed devices (public reporting on related research cites thousands of exposed Lantronix/Silex serial-to-Ethernet devices) — EDS5000 devices are niche industrial/enterprise serial-to-Ethernet console servers rather than mass-market products, but related coverage of the BRIDGE:BREAK research and internet-exposure reporting indicates thousands of these devices are…

Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.

Description

An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges.

CISA Known Exploited Vulnerability
Affected
Lantronix EDS5000
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Due date
Ransomware use
Unknown
Vendors
lantronix
Products
eds5008 firmware, eds5016 firmware, eds5032 firmware, g526gp12s firmware, g526gp17s firmware, g526gp1cs firmware, g526gp1asg firmware, g526gp1as firmware, g527gp22s firmware, g527gp27s firmware, g527gp2as firmware, g527gp2asg firmware
Weakness
CWE-78
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X