Skip to content
NewA calmer, faster ZeroHour
MalwarehighExploited in the wild

ClingSTUN Malware Turns Unpatched IoT Devices Into Proxy Nodes

Infosecurity Magazineby Alessandro Mascellino ()2 min read7 · 1 read
AI summary · grok-4.7Summaries by Vani AI

ClingSTUN exploits unpatched IoT flaws and uses public STUN servers to run proxy nodes.

FortiGuard Labs reported ClingSTUN, a Linux proxy backdoor observed exploiting unpatched flaws in internet-facing IoT devices and turning them into remotely controlled proxy nodes. The campaign used three phases and download servers, beginning with CVE-2022-36553 in Hytec Inter routers, then CVE-2025-34035 in EnGenius and CVE-2024-23625 in D-Link, before expanding to 24 vulnerabilities including Ivanti Connect Secure flaws CVE-2023-46805 and CVE-2024-21887 plus CVE-2026-36356 and CVE-2025-67038. ClingSTUN sends STUN binding requests to legitimate public servers so traffic resembles VoIP or WebRTC, reports mapped ports, kills competing processes, persists via boot scripts, masquerades using init process information, and supports remote command execution. It also carries exploits for seven additional vulnerabilities, including flaws in Realtek's SDK and DVR products, to spread.

Key facts
  • FortiGuard tracked ClingSTUN across three periods and changing download servers.
  • Entry points grew to 24 flaws, including Ivanti Connect Secure bugs.
  • Legitimate public STUN servers keep NAT mappings open and are not attacker infrastructure.
  • The backdoor persists through boot scripts, masquerades as init, and runs remote commands.
  • Hard-coded exploits for seven more vulnerabilities help it spread to other devices.
Analyze this story with Vani AIImpact, who is affected and what defenders should do, in a new chat

Vulnerabilities mentioned

All
CVEVulnerabilityCVSSEPSSSignalsPublished
CVE-2022-36553
Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi
9.891%
CVE-2024-21887
+1 related CVE
Command Injection RCE in Ivanti Connect Secure and Policy Secure
9.1
group max
91%KEVRansomwarePoC
KEV
CVE-2024-23625
A command injection vulnerability exists in D-Link DAP-1650 devices when handling UPnP SUBSCRIBE messages
9.823%
CVE-2025-34035
Unauthenticated root command injection in EnGenius EnShare
10.023%PoC ×3
CVE-2025-67038
Unauthenticated Root Command Injection in Lantronix EDS5000 Device Servers
9.33%KEV
KEV
CVE-2026-36356
The GoAhead web server on MeiG Smart FORGE_SLT711 devices (firmware MDM9607.LE.1.0-00110-STD.PROD-1) allows unauthenticated OS command injection via the…
9.114%

From the original article

2 min read at infosecurity-magazine.com

ClingSTUN exploits known IoT flaws and abuses public STUN servers to keep proxy access to devices

Infosecurity Magazine

By Alessandro Mascellino · infosecurity-magazine.com

Read the full article at Infosecurity Magazine

A short excerpt; the article and its images belong to the publisher. Summary, key facts and assessment above are AI-written from the article and can be wrong.