Skip to content
NewA calmer, faster ZeroHour

Brotli 1.0.3–1.2.0 overflow affects Siemens industrial software

Original title: Siemens Industrial Software Products

CISA Advisoriesby CISA ()3 min read1
Part of a story covered by 2 sourcesSiemens maps critical Brotli decoder flaw across industrial productsMerged summary & timeline
AI summary · x-ai/grok-4.7Summaries by Vani AI

Users should move Brotli to 1.0.10, 1.1.1, or 1.2.1; Siemens says no product fix is available.

A buffer overflow in the Google Brotli decoder, versions 1.0.3 through 1.2.0, lets a remote unauthenticated attacker corrupt decoder state with a crafted compressed stream. Effects can include memory disclosure, denial of service, or potential code execution. Siemens lists 28 industrial products as affected and says no product fix is currently available.

Unconfirmed: The provided text is truncated, so additional affected products may be omitted, and no CVE id is shown.

Key facts
  • Fixed Brotli versions named are 1.0.10, 1.1.1, and 1.2.1.
  • Opcenter products can be mitigated on the IIS Reverse Proxy.
  • PADS, Xpedition, and HyperLynx guidance is to disable and block Brotli compression.
  • Teamcenter V2412, V2506, V2512, and V2606 have separate manual mitigation instructions.
Security assessment · AI, from the article

Impact: Memory disclosure, denial of service, or potential code execution

ProductAffectedFixed in
Google Brotli1.0.3 through 1.2.01.0.10 or 1.1.1 or 1.2.1
Siemens Opcenter Execution Core——
Siemens Opcenter Execution Discrete——
Siemens Opcenter Execution Foundation——
Siemens Opcenter Execution Pharma——
Siemens Opcenter Execution Process——
Siemens Opcenter Intelligence——
Siemens Opcenter Intra Plant Logistics——
Siemens Opcenter Quality——
Siemens Opcenter RDnL——
What to do
  1. 1.Update Brotli libraries or binaries from 1.0.3 through 1.2.0 to 1.0.10, 1.1.1, or 1.2.1.
  2. 2.Apply the Siemens IIS Reverse Proxy mitigation where that guidance is listed.
  3. 3.Disable Brotli compression and block it at the firewall where Siemens advises that.
Analyze this story with Vani AIImpact, who is affected and what defenders should do, in a new chat

From the original article

3 min read at cisa.gov

View CSAF Summary On October 21, 2026, the Node. js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node. js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497).

CISA Advisories

By CISA · cisa.gov

Read the full article at CISA Advisories

A short excerpt; the article and its images belong to the publisher. Summary, key facts and assessment above are AI-written from the article and can be wrong.