Siemens Industrial Edge Management
Siemens Industrial Edge Management has a critical unauthenticated password-reset flaw enabling remote account takeover.
CISA republished Siemens ProductCERT SSA-503852 for CVE-2026-18963, a weak password-recovery flaw in Industrial Edge Management. An unauthenticated remote attacker can complete a password reset without the email verification link and take over accounts. CVSS 3.1 is 9.1. Affected ranges are Cloud (all versions), Pro V1 from 1.14.9 before 1.15.20, Pro V2 from 2.2.0 before 2.2.2, and Virtual from 2.6.0 before 2.9.1. The defect is in the Keycloak reset-credentials flow; the advisory does not report exploitation.
- CVE-2026-18963 has CVSS 9.1 and requires no authentication.
- Unauthenticated attackers can reset any user's password without email verification.
- Affected products are Edge Management Cloud, Pro V1, Pro V2, and Virtual.
- Siemens urges updates; the flaw sits in Keycloak's reset-credentials flow.
Vulnerabilities mentionedAll →
- CVE-2026-189639.13%Unauthenticated Account Takeover via Password Reset Flow in Red Hat Build of Keycloakpublished · Red Hat Build of Keycloak (keycloak-services component, reset-credentials flow) PoC
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2026-18963 |
Full article731 words · extracted from cisa.gov · click to collapse
Summary
Industrial Edge Management contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to perform full account takeover by resetting user credentials without completing email verification. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Industrial Edge Management are affected:
- Industrial Edge Management Cloud vers:all/* (CVE-2026-18963)
- Industrial Edge Management Pro V1 vers:intdot/>=1.14.9|<1.15.20 (CVE-2026-18963)
- Industrial Edge Management Pro V2 vers:intdot/>=2.2.0|<2.2.2 (CVE-2026-18963)
- Industrial Edge Management Virtual vers:intdot/>=2.6.0|<2.9.1 (CVE-2026-18963)
| CVSS | Vendor | Equipment | Vulnerabilities |
|---|---|---|---|
| v3 9.1 | Siemens | Siemens Industrial Edge Management | Weak Password Recovery Mechanism for Forgotten Password |
Background
- Critical Infrastructure Sectors: Critical Manufacturing
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-18963
A flaw was found in the reset-credentials flow of the keycloak-services component, which is the core engine for identity and access management in Red Hat Build of Keycloak. The issue allows an unauthenticated attacker to force the password reset process for any user without needing to click the required email verification link. This can result in the attacker gaining full control over target user accounts by directly setting new credentials.
Affected Products
Siemens Industrial Edge Management
Vendor:
Siemens
Product Version:
Industrial Edge Management Cloud, Industrial Edge Management Pro V1 >= V1.14.9 < V1.15.20, Industrial Edge Management Pro V2 >= V2.2.0 < V2.2.2, Industrial Edge Management Virtual >= V2.6.0 < V2.9.1
Product Status:
known_affected
Relevant CWE: CWE-640 Weak Password Recovery Mechanism for Forgotten Password
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 9.1 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N |
Acknowledgments
- Siemens ProductCERT reported this vulnerability to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
- Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolate them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-503852 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
- Initial Release Date: 2026-09-08
| Date | Revision | Summary |
|---|---|---|
| 2026-09-08 | 1 | Publication Date |