ZeroHour

Search: “cwe”

36 stories in the last 30d

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Cisco IOS XR Software Security Hardening Release: September 2026

Cisco released IOS XR security hardening fixes for multiple internally discovered vulnerabilities, grouped by CWE class, with no known active exploitation.

Cisco's IOS XR engineering team conducted a comprehensive internal security review and released hardening updates addressing multiple internally discovered vulnerabilities. The issues were found during internal testing and are not known to be actively exploited. Cisco grouped the vulnerabilities by CWE class and assigned a single CVE ID to each grouping to streamline patching and disclosure.

Cisco Security Advisories · 12d agoAdvisory

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 14d agoAdvisoryCVE-2026-75925

Cisco Crosswork Security Hardening Release: August 2026

Cisco released an August 2026 Crosswork security hardening update addressing multiple internally discovered vulnerabilities, grouped by CWE class with one CVE per grouping.

Cisco's Crosswork engineering team completed a comprehensive internal security review and shipped a hardening release fixing multiple internally discovered vulnerabilities. The issues were found during internal testing, are grouped by CWE class, and each grouping received a single CVE ID. Cisco states these vulnerabilities are not known to be actively exploited.

Cisco Security Advisories · 26d agoAdvisory

Cisco Nexus Dashboard Software Security Hardening Release: September 2026

Cisco released Nexus Dashboard hardening updates for multiple internally discovered vulnerabilities, grouped by CWE and not known to be exploited.

Cisco's Nexus Dashboard engineering team conducted an internal security review that found multiple vulnerabilities, addressed via software hardening releases. The issues were discovered during internal testing and are not known to be actively exploited. Cisco grouped the issues by CWE class and assigned a single CVE ID per issue before releasing fixes.

Cisco Security Advisoriesupdated · 15m agofirst · 20h agoAdvisory 2 sources

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 14d agoAdvisoryCVE-2026-4827

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 2d agoAdvisoryCVE-2026-80465

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 2d agoAdvisoryCVE-2026-81861

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 2d agoAdvisoryCVE-2026-58113

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 7d agoAdvisoryCVE-2026-87020

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 9d agoAdvisoryCVE-2026-85083

AL26-019 - Vulnerabilities impacting Citrix NetScaler ADC and NetScaler Gateway - CVE-2026-19490 and CVE-2026-19489

Canadian Cyber Centre alerts on Citrix NetScaler ADC/Gateway flaws CVE-2026-19490 (authentication bypass) and CVE-2026-19489 (buffer overflow), urging emergency patching.

The Canadian Centre for Cyber Security issued alert AL26-019 covering two Citrix NetScaler vulnerabilities disclosed in a vendor advisory on August 19, 2026. CVE-2026-19490 (CWE-288) allows a remote unauthenticated attacker to bypass authentication on appliances configured as a Gateway for SSL VPN, ICA Proxy, CVPN, RDP Proxy, or as an AAA virtual server. CVE-2026-19489 (CWE-120) is a classic buffer overflow that may cause memory overflow, unpredictable behavior, or denial-of-service conditions. Affected appliances are vulnerable when configured as a SAML IdP; fixed versions include 14.1-73.32, 13.1-63.21, and 13.1-37.277 for FIPS.

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 14d agoAdvisoryCVE-2026-78012

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 14d agoAdvisoryCVE-2026-77477

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 14d agoAdvisoryCVE-2026-77393

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

Cisco Secure Workload Software Security Hardening Release: August 2026

Cisco shipped August 2026 hardening releases for Secure Workload fixing multiple internally discovered vulnerabilities that are not actively exploited.

Cisco's Secure Workload engineering team completed an internal security review that found multiple vulnerabilities during internal testing. The issues are grouped by CWE class with a single CVE assigned per grouping, and none are known to be actively exploited. Cisco has released hardening updates for customers to patch.

Cisco Security Advisories · 28d agoAdvisory

Workflow session email approval process bypass

Fortinet disclosed an improper access control flaw (CVSS 4.7) in FortiManager allowing administrators to bypass workflow session email approval via crafted HTTP requests.

Fortinet advisory FG-IR-26-171 covers an improper access control vulnerability (CWE-284) in FortiManager, rated CVSSv3 4.7. An administrator can bypass the approval process for workflow sessions via crafted HTTP or HTTPS requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Improper Authentication of FortiPAM Server

Fortinet discloses CVSS 9.1 improper authentication in FortiPAM's Chrome extension allowing unauthenticated attackers to proxy victims' browser traffic.

Fortinet advisory FG-IR-26-168 describes an improper authentication vulnerability (CWE-287) rated 9.1 in the Fortinet Privileged Access Agent Chrome Extension. A remote unauthenticated attacker could proxy a user's browser traffic through attacker-controlled servers if the user visits a malicious website. The advisory was revised on September 8, 2026.

Fortinet PSIRT · 9d agoAdvisory

Open Redirect on FortiSIEM

Fortinet disclosed an open redirect flaw (CVSS 2.8) in FortiSIEM allowing authenticated attackers to redirect users to arbitrary websites via crafted HTTP requests.

Fortinet advisory FG-IR-26-169 covers an open redirect vulnerability (CWE-601) in FortiSIEM, rated CVSSv3 2.8. An authenticated attacker can cause a redirection to any website via specially crafted HTTP requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

JWT used for authentication in web GUI signed with static key

Fortinet warns that FortiMonitorOnSight's web GUI uses JWTs signed with a static key, enabling remote unauthenticated authentication bypass.

Fortinet advisory FG-IR-26-170 discloses a CVSS 9.6 vulnerability (CWE-540, sensitive information in source code) in the FortiMonitorOnSight web portal. The web GUI's JWT authentication tokens are signed with a static key, allowing a remote unauthenticated attacker to bypass authentication via forged or reused JWTs. The advisory was revised on September 8, 2026.

Fortinet PSIRT · 9d agoAdvisory

Broken Access control on Websocket streams

Fortinet FortiSOAR access control flaw (CVSS 4.9) lets zero-permission authenticated attackers subscribe to and inject broadcast messages into websocket streams.

Fortinet advisory FG-IR-26-164 discloses an improper access control vulnerability (CWE-284, CVSSv3 4.9) in FortiSOAR. An authenticated attacker with zero permissions can subscribe to websocket streams and topics and inject broadcast messages via crafted websocket requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Null Pointer Dereference in Log Report

Fortinet patched a low-severity null pointer dereference (CVSS 2.5) in FortiOS, FortiProxy, and FortiPAM that lets authenticated attackers crash the httpsd daemon.

Fortinet advisory FG-IR-26-173 describes a NULL pointer dereference vulnerability (CWE-476) in FortiOS, FortiProxy, and FortiPAM, scored CVSSv3 2.5. An authenticated attacker can crash the httpsd daemon via crafted HTTP requests, causing a denial of service. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Arbitrary process termination from exposed minifilter communication port

Fortinet FortiClient Windows fortimon3 driver flaw (CVSS 4.7) lets authenticated attackers terminate arbitrary processes via exposed minifilter communication port.

Fortinet advisory FG-IR-26-165 discloses an unverified ownership vulnerability (CWE-283, CVSSv3 4.7) in the FortiClient Windows fortimon3 minifilter driver. An authenticated attacker can terminate arbitrary processes through an exposed minifilter communication port. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory1

ZTNA Portal Improper Certificate Validation

Fortinet fixed an improper certificate validation flaw (CVSS 7.3) in FortiOS and FortiProxy Agentless ZTNA portal enabling unauthenticated man-in-the-middle attacks on backend traffic.

Fortinet advisory FG-IR-26-174 discloses an improper certificate validation vulnerability (CWE-295) in the FortiOS and FortiProxy Agentless ZTNA portal, rated CVSSv3 7.3. A remote and unauthenticated attacker can perform a man-in-the-middle attack on the communication channel between the ZTNA portal and the backend destination website. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Uncontrolled Resource Consumption in SNMP

Uninitialized variable flaw (CVSS 5.9) in FortiAnalyzer's SNMP daemon lets remote authenticated attackers cause denial of service via SNMP GETBULK requests.

Fortinet advisory FG-IR-26-172 describes a use of uninitialized variable vulnerability (CWE-457) in the FortiAnalyzer SNMP daemon, scored CVSSv3 5.9. A remote authenticated attacker with user-level permissions can cause a denial of service via SNMP GETBULK requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Cron Job Injection in Remote Backup

Fortinet FortiSandbox command injection flaw (CVSS 6.7) in remote backup cron jobs lets privileged attackers execute arbitrary code via crafted HTTP requests.

Fortinet advisory FG-IR-26-167 discloses a command injection vulnerability (CWE-77, CVSSv3 6.7) in FortiSandbox's remote backup cron job functionality. A privileged attacker can execute unauthorized code or commands via crafted HTTP requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory

Unauthenticated Control of NAT Rules Leading to Exposure of Sensitive Information

Fortinet fixed an improper access control flaw (CVSS 8.9) in FortiSandbox, FortiSandbox Cloud, and FortiSandbox PaaS letting unauthenticated attackers access sensitive information.

Fortinet advisory FG-IR-26-166 discloses an improper access control vulnerability (CWE-284) in the FortiSandbox, FortiSandbox Cloud, and FortiSandbox PaaS web UI, rated CVSSv3 8.9. The advisory title indicates unauthenticated control of NAT rules leading to exposure of sensitive information. An unauthenticated attacker can access sensitive data via crafted HTTP requests. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory