CISA Red Team Fully Compromised Two Critical Infrastructure Orgs
CISA red teams achieved full domain and cloud compromise at two critical infrastructure orgs; one SOC never detected the intrusion.
CISA advisory AA26-237A documents two simultaneous red team assessments. Organization A (Government Services sector) missed the intrusion entirely, as default credentials on a web app, ADCS ESC1 abuse, and thousands of false-positive alerts let the red team reach sensitive business systems and read SOC email. Organization B (Water/Wastewater sector) detected, isolated, and reimaged hosts quickly, but both orgs lacked Conditional Access for workload identities, and B still exposed DCSync, Golden Ticket, and OT network attack paths.
CISA Updates Insider Threat Guide With New Mitigation Advice
CISA updated its Insider Threat Mitigation Guide on September 9 with new case studies and guidance on hybrid work, AI and employee separations.
CISA published a revision of its Insider Threat Mitigation Guide, first issued in 2020, adding case studies, statistics and guidance for security, HR and leadership audiences. New material covers hybrid and remote work changes to physical and digital access, AI used to manipulate or deceive, access control, visitor screening and adverse employee separations. The agency framed the update around growing insider threat impact on critical infrastructure and pointed to preparedness resources for organizations without existing programs.
Water sector passes, government sector fails attempts to spot and halt simulated CISA attack
CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.
CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.
AI agent authorization risks remain a gap in new NIST-CISA token security guidance
NIST and CISA release IR 8587 guidance on securing signed tokens, but AI agent authorization and delegation risks remain out of scope.
NIST, with CISA support, published 'Protecting Tokens and Assertions from Forgery, Theft, and Misuse' (NIST IR 8587), recommending continuous monitoring and tighter token lifecycle controls for SSO and API access. The guidance does not yet fully address AI agent identity, delegation chains, or prompt injection steering agents with valid tokens, and NIST says new or expanded standards are needed. Experts recommend treating AI agents as low-trust non-human identities, maintaining agent inventories, expiring credentials after task completion, and requiring human approval for high-risk actions. The report references shared-signal mechanisms like CAEP and RISC, and follows a May incident where a CISA contractor GitHub repository exposed AWS and GitHub tokens.
CISA Red Team Compromised Two Critical Infrastructure Orgs, One Detected Nothing
CISA red teams fully compromised two critical infrastructure orgs with similar tradecraft; one detected nothing, the other contained phishing within minutes.
CISA advisory AA26-237A, 'A Tale of Two SOCs,' describes two simultaneous red team assessments of a Government Services organization and a Water and Wastewater Systems organization, both compromised to the domain level. Organization A never detected the intrusion, enabled by default credentials, a misconfigured AD CS template (ESC1), cleartext credentials, non-expiring static AWS keys, and over-permissioned Entra ID applications. Organization B detected and isolated phishing within 2-20 minutes, though the red team still reached krbtgt via DCSync from cleartext SCCM credentials. CISA attributes the outcome gap to people and processes rather than the security tools themselves.
Siemens Reyrolle 7SR5
CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.
CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.
Schneider Electric SCADAPack x70 Products
CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.
CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.
CISA Urges Service Providers to Provide Transparent Updates During Major IT and OT Outages
CISA and FBI issued guidance urging service providers to deliver timely, transparent communications during major IT and OT outages.
CISA, with the FBI and international partners, released 'Communicating Under Pressure: Best Practices for Service Providers', urging providers to prepare crisis-communication procedures, provide timely status updates during IT/OT outages, and maintain out-of-band communication channels. The guidance warns that disruptions to telecom, cloud, energy, and water services can cascade across critical infrastructure. It aligns with CISA's CI Fortify initiative supporting IT/OT isolation and recovery.
IXON VPN Client
CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.
IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.
Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)
CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.
CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.
CISA's logging guidance works beyond government
CISA released its Logging Reference Architecture in August 2026 to help federal agencies meet OMB M-26-14 logging requirements, usable as a benchmark by critical infrastructure operators.
CISA's Logging Reference Architecture (LRA), released in August 2026, helps US federal civilian agencies satisfy logging requirements in OMB Memorandum M-26-14 and explicitly encourages critical infrastructure operators to use it as a benchmark. The framework is organized around continuous event monitoring and threat hunting, investigation, response, and forensics, with a federal baseline of six months searchable and one year retrievable logs. Agencies must submit Agency Logging Plans within 90 days and work toward Advanced maturity within 320 days; the guidance also treats AI outputs as derived data requiring human review and preserved metadata.
CISA and NIST Issue Guidance to Protect Cloud Identity Tokens
CISA and NIST published Interagency Report 8587 with voluntary guidance to harden cloud identity tokens against theft, forgery, and lateral movement.
CISA and NIST released NIST Interagency Report 8587 on September 15 with final voluntary guidance for federal agencies, cloud providers, and their customers on protecting SSO, federation, and API tokens. Requirements include one-hour maximum token lifetimes, 90-day signing key rotation for high-impact systems, hardware-backed key storage, explicit audience fields, and keeping tokens out of logs. The guidance was motivated by the 2020 ADFS compromise where forged SAML assertions bypassed MFA, and an incident where a leaked consumer signing key enabled token forgery and theft of 60,000+ emails from one agency. Nearly 250 public comments shaped the text, with input from Google, Microsoft, Okta, AWS, Oracle, IBM, HashiCorp, Wiz, and the OpenID Foundation via the Joint Cyber Defense Collaborative.
Siemens Mendix SAML
Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).
CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.
CareCam CM2507
CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.
CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.