ZeroHour

Search: “defense automation”

33 stories

China-Based Artificial Intelligence Companies Conducting Industrial-Scale Distillation Campaigns Against U.S. AI Companies

NSA, CISA, and FBI warn DeepSeek, Alibaba, and other Chinese AI firms ran industrial-scale distillation of U.S. frontier models, threatening U.S. AI leadership.

A joint NSA, CISA, and FBI Cybersecurity Advisory (AA26-251A) says China-based firms DeepSeek, Moonshot AI, Alibaba, MiniMax, StepFun, and Z.AI extracted billions of tokens from U.S. frontier models including Claude, GPT, Gemini, and Grok, likely with Chinese government knowledge. Campaigns running since at least late 2024 used native APIs, cloud providers, third-party aggregators, gray-market proxy "transfer stations", and shared premium subscriptions to bypass geographic restrictions, evade safeguards, and violate providers' terms of use. The agencies recommend detecting anomalous prompts, accounts, and usage patterns; subtly altering responses to suspected distillers; and cross-organization intelligence sharing. They also call DeepSeek's publicly cited $5.6M training cost misleading because it excludes data acquired through distillation.

CISA Advisories · 10d agoAdvisory in the wild1

ENISA: Frontier AI Is Changing the Speed of Cyberattacks. Europe Needs to Catch Up

ENISA warns frontier AI compresses attack lifecycles to minutes, with exploits possible within 15 minutes of disclosure and median 72-minute breach-to-exfiltration times.

ENISA's July 2026 paper 'ENISA's view on Cybersecurity in the Frontier AI Era' argues AI-assisted attackers may weaponize vulnerabilities within 15 minutes of disclosure and achieve initial-access-to-data-exfiltration in a median 72 minutes, creating a 'negative time-to-exploit' problem. The report cites one organisation whose CVE volume rose from roughly 80 in Q1 2025 to almost 500 in Q1 2026, then about 500 reports per day when frontier-AI tools were used. ENISA recommends machine-speed defence under 'Cybersecurity as Code', EPSS and VEX-based prioritisation, AI-assisted incident response with human oversight, and an assume-breached architecture.

Security Affairs · 3d agoAdvisory

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 15d agoAdvisoryCVE-2026-77393

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 15d agoAdvisoryCVE-2026-77477

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 29d agoAdvisory in the wild

Schneider Electric Modicon M340 Controller and Communication Modules

CISA warns CVE-2025-6625 lets unauthenticated attackers crash Schneider Electric Modicon M340 controllers and communication modules via a crafted FTP command.

Schneider Electric advisory SEVD-2025-224-05, republished by CISA, describes CVE-2025-6625 (CWE-20 improper input validation) in Modicon M340 controllers and X80 Ethernet, M580 Global Data, and Modbus/TCP modules. A crafted FTP command sent to an affected device causes denial of service, with CVSS v3.1 base score 7.5. Fixes are available, including firmware SV3.70 for the Modicon M340 controller.

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 3d agoAdvisoryCVE-2026-81861

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 15d agoAdvisoryCVE-2026-4827

Best Practices for Good Endpoint Hardening | Huntress

Huntress outlines endpoint hardening best practices, citing exposed RDP, RMM tool abuse, and ClickFix social engineering as common SMB intrusion paths.

Huntress published defensive guidance on endpoint hardening for small and mid-sized businesses, drawing on observations from its SOC. The post describes common intrusion vectors: internet-exposed RDP brute-forced by automated scanners, phishing emails delivering attacker-controlled remote monitoring and management (RMM) tools, with Huntress reporting a 277% spike in RMM abuse in 2025, and ClickFix attacks using fake CAPTCHA pages that trick users into running malicious commands. Recommended controls include scanning for exposed RDP, SSH, and VPN interfaces, removing unneeded local admin rights, enabling Windows Defender tamper protection, disabling SMBv1, and standardizing on one approved remote access tool, guided by CIS and NIST frameworks.

Huntress · 7d agoAdvisory

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

CISA and NIST Release Technical Checklist for Safeguarding Identity Tokens From Theft and Misuse

CISA and NIST published NIST IR 8587, final guidance for protecting identity tokens from forgery, theft, replay, and signing-key compromise.

NIST Interagency Report 8587 (September 15, 2026) expands the IA-13 'Identity Providers and Authorization Servers' control from NIST SP 800-53 R5.1.1, guiding federal agencies and cloud providers on SSO, identity federation, and machine-to-machine authentication. It requires hardware-backed signing-key storage for moderate-impact systems, 90-day key rotation for high-impact systems, token lifetimes under one hour, and sender-constrained mechanisms such as mutual TLS and DPoP. The report cites incidents including forged SAML assertions that exposed over 60,000 emails from a federal agency. It also extends guidance to agentic AI systems using signed tokens and urges post-quantum cryptography migration planning.

Cyber Security News · 2d agoAdvisory1

CISA Urges Service Providers to Provide Transparent Updates During Major IT and OT Outages

CISA and FBI issued guidance urging service providers to deliver timely, transparent communications during major IT and OT outages.

CISA, with the FBI and international partners, released 'Communicating Under Pressure: Best Practices for Service Providers', urging providers to prepare crisis-communication procedures, provide timely status updates during IT/OT outages, and maintain out-of-band communication channels. The guidance warns that disruptions to telecom, cloud, energy, and water services can cascade across critical infrastructure. It aligns with CISA's CI Fortify initiative supporting IT/OT isolation and recovery.

GBHackers · 7d agoAdvisory

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 9d agoAdvisory in the wild