ZeroHour

Search: “deployment”

23 stories

China-Based Artificial Intelligence Companies Conducting Industrial-Scale Distillation Campaigns Against U.S. AI Companies

NSA, CISA, and FBI warn DeepSeek, Alibaba, and other Chinese AI firms ran industrial-scale distillation of U.S. frontier models, threatening U.S. AI leadership.

A joint NSA, CISA, and FBI Cybersecurity Advisory (AA26-251A) says China-based firms DeepSeek, Moonshot AI, Alibaba, MiniMax, StepFun, and Z.AI extracted billions of tokens from U.S. frontier models including Claude, GPT, Gemini, and Grok, likely with Chinese government knowledge. Campaigns running since at least late 2024 used native APIs, cloud providers, third-party aggregators, gray-market proxy "transfer stations", and shared premium subscriptions to bypass geographic restrictions, evade safeguards, and violate providers' terms of use. The agencies recommend detecting anomalous prompts, accounts, and usage patterns; subtly altering responses to suspected distillers; and cross-organization intelligence sharing. They also call DeepSeek's publicly cited $5.6M training cost misleading because it excludes data acquired through distillation.

CISA Advisories · 8d agoAdvisory in the wild1

Microsoft Confirms Remote Desktop Services Might Stop Working Following Sept. 2026 Security Update

Microsoft's September 2026 Patch Tuesday updates (KB5124008) can break Remote Desktop Services, causing RDP failures and freezes across Windows clients and servers.

Microsoft confirmed its September 2026 security updates, including KB5124008 for Windows 11 24H2/25H2, introduced a reliability regression where RDP connections fail after several minutes and servers hang at the 'Please wait for the Remote Desktop Configuration' screen. MMC, RDS Licensing Diagnoser, File Explorer, and the Windows Update settings page may also stop responding. The issue affects Windows 10/11 clients and Windows Server 2012 through 2025; Microsoft marked it Mitigated on September 11 and is developing a permanent fix, with VM restart offered as a temporary workaround.

Cyber Security News · 2d agoAdvisory

September 2026 Patch Tuesday forecast: All we need is more time

September 2026 Patch Tuesday forecast expects record CVE volume after August's 398 fixes, with SharePoint flaws CVE-2026-55040 and CVE-2026-63520 actively exploited.

This Patch Tuesday forecast column notes August 2026 Patch Tuesday was the second largest ever with 398 resolved CVEs, yet only one was confirmed actively exploited. SharePoint flaws CVE-2026-55040 and CVE-2026-63520 are being chained for authentication bypass and remote code execution in active attacks against unpatched servers. Microsoft Defender's ShieldBreak elevation of privilege flaw (CVE-2026-69414) is publicly disclosed with PoC code and a fix is expected, while Chrome CVE-2026-85046 was reported exploited in the wild. Several products, including Windows 11 24H2 Home/Pro and Exchange Server 2016/2019 ESU, reach end of support in October 2026.

Help Net Security · 7d agoAdvisory in the wildCVE-2026-55040CVE-2026-63520CVE-2026-62911+5 CVEs1

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Microsoft Confirms KB5002914 Update Breaks Copy and Paste on Excel

Microsoft confirms KB5002914 Excel security update silently breaks copy-paste in Excel 2016-2024, forcing admins to choose between usability and security fixes.

Microsoft added a known issue to KB5002914, the September 8, 2026 Excel security update, where paste, autofill, and formula dragging fail silently with no error in Excel 2016, 2019, 2021, and 2024. The update addresses remote code execution and information disclosure flaws including CVE-2026-81399, CVE-2026-81390, and CVE-2026-81954. No hotfix date has been published as of September 15, 2026; the only widely confirmed recovery is uninstalling or rolling back KB5002914, which drops the month's Excel security fixes.

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

CISA Advisoriesupdated · 5d agofirst · 6d agoAdvisory 2 sourcesCVE-2026-82583CVE-2026-78224CVE-2026-82578

Tycon Systems TPDIN-Monitor-WEB3

CISA reports three flaws (hard-coded credentials, CSRF, missing authorization) in Tycon TPDIN-Monitor-WEB3 <=2.2.9 enabling MitM, credential theft, or device resets.

CISA published ICSA-26-246-08 for Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior, covering CVE-2026-77847 (use of hard-coded credentials, CWE-798), CVE-2026-82712 (CSRF, CWE-352), and CVE-2026-82684 (missing authorization, CWE-862). Exploitation could enable man-in-the-middle attacks, factory resets, credential wiping, or extraction of system credentials, configurations, and flash contents; the CSRF issue scores CVSS 8.8. No public exploitation has been reported; CISA recommends isolating devices from business networks.

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 13d agoAdvisoryCVE-2026-77393

Cisco Identity Services Engine RADIUS Denial of Service Vulnerability

Cisco patched a RADIUS flaw in Identity Services Engine letting unauthenticated remote attackers trigger denial of service on ISE nodes.

A vulnerability in the RADIUS feature of Cisco Identity Services Engine allows an unauthenticated remote attacker to cause a denial of service by sending crafted RADIUS requests directly to an affected device. The flaw stems from improper handling of certain RADIUS requests and can render ISE nodes unavailable. In single-node deployments, endpoints that have not yet authenticated would be unable to access the network until the node recovers. Cisco has released software updates addressing the issue.

Microsoft releases Windows 10 KB5122878 extended security update

Microsoft shipped Windows 10 ESU update KB5122878, delivering the record September 2026 Patch Tuesday fixes, including patches for two actively exploited zero-days.

Microsoft released KB5122878 for Windows 10 Enterprise LTSC and ESU customers, moving builds 19045/19044 to .7725 with security and bug fixes. The update carries this month's record September 2026 Patch Tuesday set, which fixed 966 Microsoft vulnerabilities including two actively exploited zero-day flaws. It also fixes BitLocker recovery-key prompts and Remote Desktop audio redirection, and updates Secure Boot certificate rollout and Morocco time zone data. Microsoft reports no known issues with the update.

BleepingComputer · 8d agoAdvisory in the wild

Jenkins security advisory (AV26-877)

Canada's Cyber Centre relayed a Jenkins advisory (AV26-877) covering core and numerous plugin vulnerabilities fixed in 2.568.3/2.580.

The Canadian Centre for Cyber Security published advisory AV26-877 for the Jenkins security advisory dated September 2, 2026. Affected products include Jenkins releases other than 2.568.3 and 2.580, plus plugins such as GitLab, LDAP, Microsoft Entra ID, SAML, Script Security, Pipeline Build Step, and others. Administrators are encouraged to review the linked advisory and apply necessary updates.

Canadian Centre for Cyber Security · 13d agoAdvisory

Rockwell Automation FactoryTalk Activation Manager

CISA details CVE-2026-16675, a CVSS 7.8 privilege escalation flaw in Rockwell FactoryTalk Activation Manager V5.02 and below, with vendor fixes available.

CISA issued an ICS advisory for Rockwell Automation FactoryTalk Activation Manager. CVE-2026-16675 is a privilege escalation vulnerability stemming from installer custom actions, scored 7.8. Versions V5.02 and below are affected, and Rockwell Automation has released fixes.

CISA Advisories · 15d agoAdvisoryCVE-2026-16675

Rockwell Automation RSLinx Classic

CISA flags four flaws (CVE-2026-9621/9622/9624/9625) in Rockwell RSLinx Classic 4.50 and below that can cause denial-of-service conditions; CVSS 8.6.

CISA published an ICS advisory covering four vulnerabilities in Rockwell Automation RSLinx Classic versions 4.50 and below. The integer overflow, underflow, and classic buffer overflow flaws (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) could let attackers cause denial-of-service conditions. The product is deployed worldwide, primarily in critical manufacturing.

Rockwell Automation Historian ME

CISA warns CVE-2025-12768 and CVE-2026-12661 in Rockwell Historian ME could crash devices or allow remote code execution via out-of-bounds writes; CVSS 8.

CISA issued an ICS advisory for Rockwell Automation Historian ME Series B 5.202 and Series C 7.101. CVE-2025-12768 and CVE-2026-12661 involve out-of-bounds write and stack-based buffer overflow flaws that could crash the accessed device or enable remote code execution. The product is deployed across chemical, critical manufacturing, healthcare, and water and wastewater sectors worldwide.

Slovakia Warns of Cyber Risks in Road Speed Cameras

Slovakia's NBÚ warns that speed camera systems from SODASUS, Simicon and NEROline pose cyber risks including undocumented remote access.

Slovakia's National Security Authority (NBÚ) warned of a significant cyber threat tied to several road speed camera products: NERO R-ONE units sold by Cyprus-based SODASUS, and Cordon-series cameras made by Russia's Simicon and sold by Croatia's NEROline. A security analysis requested by the Interior Ministry found weak protections, mismatches between documented and actual communication settings and software versions, unclear hardware/software provenance, and pre-configured remote-access mechanisms outside operator control. NBÚ warned that compromised cameras could expose vehicle and licence-plate data, tamper with records, or serve as a foothold into public-sector networks lacking segmentation. The Interior Ministry reportedly removed the units from its pilot deployment and asked the supplier to replace them with equipment meeting Slovak and EU security requirements.

Security Affairs · 23d agoAdvisory