ZeroHour

Search: “intrusion”

66 stories

Best Practices for Good Endpoint Hardening | Huntress

Huntress outlines endpoint hardening best practices, citing exposed RDP, RMM tool abuse, and ClickFix social engineering as common SMB intrusion paths.

Huntress published defensive guidance on endpoint hardening for small and mid-sized businesses, drawing on observations from its SOC. The post describes common intrusion vectors: internet-exposed RDP brute-forced by automated scanners, phishing emails delivering attacker-controlled remote monitoring and management (RMM) tools, with Huntress reporting a 277% spike in RMM abuse in 2025, and ClickFix attacks using fake CAPTCHA pages that trick users into running malicious commands. Recommended controls include scanning for exposed RDP, SSH, and VPN interfaces, removing unneeded local admin rights, enabling Windows Defender tamper protection, disabling SMBv1, and standardizing on one approved remote access tool, guided by CIS and NIST frameworks.

Huntress · 6d agoAdvisory

CISA Red Team Fully Compromised Two Critical Infrastructure Orgs

CISA red teams achieved full domain and cloud compromise at two critical infrastructure orgs; one SOC never detected the intrusion.

CISA advisory AA26-237A documents two simultaneous red team assessments. Organization A (Government Services sector) missed the intrusion entirely, as default credentials on a web app, ADCS ESC1 abuse, and thousands of false-positive alerts let the red team reach sensitive business systems and read SOC email. Organization B (Water/Wastewater sector) detected, isolated, and reimaged hosts quickly, but both orgs lacked Conditional Access for workload identities, and B still exposed DCSync, Golden Ticket, and OT network attack paths.

Security Affairs · 21d agoAdvisory1

CISA and NIST Issue Guidance to Protect Cloud Identity Tokens

CISA and NIST published Interagency Report 8587 with voluntary guidance to harden cloud identity tokens against theft, forgery, and lateral movement.

CISA and NIST released NIST Interagency Report 8587 on September 15 with final voluntary guidance for federal agencies, cloud providers, and their customers on protecting SSO, federation, and API tokens. Requirements include one-hour maximum token lifetimes, 90-day signing key rotation for high-impact systems, hardware-backed key storage, explicit audience fields, and keeping tokens out of logs. The guidance was motivated by the 2020 ADFS compromise where forged SAML assertions bypassed MFA, and an incident where a leaked consumer signing key enabled token forgery and theft of 60,000+ emails from one agency. Nearly 250 public comments shaped the text, with input from Google, Microsoft, Okta, AWS, Oracle, IBM, HashiCorp, Wiz, and the OpenID Foundation via the Joint Cyber Defense Collaborative.

Infosecurity Magazine · 17h agoAdvisory

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

CISA Advisoriesupdated · 5d agofirst · 6d agoAdvisory 2 sourcesCVE-2026-82583CVE-2026-78224CVE-2026-82578

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

September 2026 Patch Tuesday: Record patch count, 2 zero-days, and a SigRed successor

Microsoft's September 2026 Patch Tuesday delivers a record patch count, fixing two exploited zero-days and a wormable DNS flaw dubbed a SigRed successor.

Microsoft's September 2026 Patch Tuesday sets another record patch count, fixing two vulnerabilities exploited as zero-days: CVE-2026-81963, a Windows Update Stack low-privilege-to-SYSTEM escalation reported by MSTIC, and CVE-2026-85880, a Windows Advanced Local Procedure Call escalation reported by Proofpoint. Zero Day Initiative's Dustin Childs urges priority on a cluster of 20 potentially wormable bugs including DNS RCE CVE-2026-69730, described as a spiritual successor to SigRed, plus Kerberos authentication bypass CVE-2026-69676 that could give any authenticated domain user RCE on domain controllers, and Exchange RCE CVE-2026-55007 via a malicious Visio attachment. All Windows fixes are bundled in cumulative updates, and experts stress prioritizing exploitable, reachable flaws over raw patch counts.

Help Net Security · 7d agoAdvisory in the wildCVE-2026-81963CVE-2026-85880CVE-2026-69730+4 CVEs

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

7th September – Threat Intelligence Report

Check Point weekly bulletin: exploited SonicWall SMA 1000 zero-days (CVE-2026-83548/49), JFrog Artifactory auth bypass, and a 2.8M-patient Baylor Genetics breach.

Check Point's weekly bulletin covers breaches including Thomson Reuters' C-Track platform (court records across 11 US states and Canada), Baylor Genetics (2.8M patients and employees, SSNs included), Hit casinos in Slovenia, and Dropbox (~5,000 accounts via abused Lenovo email verification). SonicWall patched two exploited SMA 1000 zero-days, including CVE-2026-83548, a CVSS 10.0 pre-authentication SSRF, while JFrog fixed exploited authentication bypass CVE-2026-82329 (CVSS 9.8). Malware and actor coverage includes Gambling Goblin, JSCeal, Mirage Kitten's NodeRabbit/PollCat campaign, and DPRK Contagious Interview macOS activity, plus a FalconFlank privilege-escalation PoC against CrowdStrike Falcon.

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 13d agoAdvisoryCVE-2026-77393

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 13d agoAdvisoryCVE-2026-77477

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

CISA Red Team Compromised Two Critical Infrastructure Orgs, One Detected Nothing

CISA red teams fully compromised two critical infrastructure orgs with similar tradecraft; one detected nothing, the other contained phishing within minutes.

CISA advisory AA26-237A, 'A Tale of Two SOCs,' describes two simultaneous red team assessments of a Government Services organization and a Water and Wastewater Systems organization, both compromised to the domain level. Organization A never detected the intrusion, enabled by default credentials, a misconfigured AD CS template (ESC1), cleartext credentials, non-expiring static AWS keys, and over-permissioned Entra ID applications. Organization B detected and isolated phishing within 2-20 minutes, though the red team still reached krbtgt via DCSync from cleartext SCCM credentials. CISA attributes the outcome gap to people and processes rather than the security tools themselves.

The Hacker News · 21d agoAdvisory

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 28d agoAdvisory in the wild