ZeroHour

Search: “control systems”

902 stories in the last 30d

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

I Think the Military Commissary Freezers Were Hacked

Refrigeration failures at six-plus US military commissaries prompt speculation of a cyber attack on DeCA's remote monitoring systems; Pentagon acknowledges possible disruption.

The author documents near-simultaneous freezer and refrigeration failures at confirmed installations including Fort Huachuca, F.E. Warren AFB, Fort Irwin and Travis AFB on August 26-27, with freezers entering defrost mode that heated and spoiled food. DeCA's Remote Monitoring Control System controls defrost across roughly 182 locations, and an unverified comment attributed the Fort Huachuca failure to a network issue. Stars and Stripes and Military Times independently reported the multi-base failures, and the Pentagon acknowledged a 'possible refrigeration disruption,' though no evidence of hacking has been confirmed.

Lobsters · security · 13d agoData breach

[Control Systems] National Instruments security advisory (AV26-914)

Canada's Cyber Centre relayed a National Instruments advisory covering improper access control and cleartext sensitive-information flaws in NI SystemLink and SystemLink Server.

Advisory AV26-914, dated September 11, 2026, notes that NI SystemLink and SystemLink Server prior to or equal to 2026 Q3 Patch 1 are affected by improper access controls and storage of sensitive information in cleartext. The Canadian Centre for Cyber Security urges users and administrators to review the vendor's links and apply available security updates.

Canadian Centre for Cyber Security · 4d agoAdvisory2

[Control Systems] Siemens security advisory (AV26-890)

Canada's Cyber Centre relayed a Siemens advisory affecting Reyrolle 7SR5, Teamcenter, Siveillance Control, Desigo CC and other products.

Advisory AV26-890, dated September 8, 2026, flags Siemens vulnerabilities in Reyrolle 7SR5 (versions prior to V2.70), Teamcenter, Siveillance Control, SIMATIC AX Runtime, Desigo CC, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT across multiple versions and models. The Cyber Centre encourages users and administrators to review the Siemens advisory and apply available updates. No specific CVEs or exploitation details are provided in the relayed advisory.

Canadian Centre for Cyber Security · 7d agoAdvisory

[Control systems] GeoVision security advisory (AV26-913)

Canada's Cyber Centre (AV26-913) warns GeoVision GV-LPC2011/LPC2211 firmware 1.13 license-plate cameras are affected by vulnerabilities and urges updates.

The Canadian Centre for Cyber Security issued control-systems advisory AV26-913 on September 11, 2026, noting that GeoVision GV-LPC2011/LPC2211 firmware version 1.13 is affected by vulnerabilities. The bulletin references the vendor advisory GV-LPC-2026-09-01 but provides no CVE identifiers or exploitation details. Administrators are encouraged to review the linked advisories and apply updates as they become available.

Canadian Centre for Cyber Security · 4d agoAdvisory

[Control systems] Schneider Electric security advisory (AV26-912)

Canada's Cyber Centre relays a Schneider Electric advisory covering multiple vulnerabilities in EcoStruxure IT Data Center Expert and PowerLogic T300, urging users to apply updates.

The Canadian Centre for Cyber Security issued advisory AV26-912 noting that as of September 9, 2026 Schneider Electric is affected by vulnerabilities in EcoStruxure IT Data Center Expert versions 9.1.2 and prior, and PowerLogic T300 versions 2.9.8-5620 and prior. The issues include an improper neutralization of special elements used in an OS command on the PowerLogic T300. The advisory recommends reviewing vendor notifications, performing suggested mitigations, and applying necessary updates.

Canadian Centre for Cyber Security · 4d agoAdvisory

[Control systems] Advantech security advisory (AV26-907)

Canada's Cyber Centre flagged vulnerabilities in the Advantech WISE-6610 industrial gateway and urged users to apply available updates.

Advisory AV26-907, dated September 10, 2026, states that multiple versions and models of the Advantech WISE-6610 industrial gateway are affected by vulnerabilities. The Canadian Centre for Cyber Security encourages users and administrators to review the provided links and apply updates as they become available. No CVE identifiers or exploitation details were included in the announcement.

Canadian Centre for Cyber Security · 5d agoAdvisory

[Control Systems] Inductive Automation security advisory (AV26-892)

Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.

The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.

Canadian Centre for Cyber Security · 7d agoAdvisory

[Control Systems] Siemens security advisory (AV26-881)

Siemens patched an account hijacking vulnerability in the Mendix SAML module affecting Mendix 9.24, 10, and 11 releases before fixed versions.

The Canadian Centre for Cyber Security relayed Siemens advisory SSA-887643, which addresses an account hijacking vulnerability in the Mendix SAML module. Affected components are the Mendix 10 and Mendix 11 compatible modules prior to V4.2.3 and the Mendix 9.24 compatible module prior to V3.6.27. Administrators are encouraged to review the linked advisories and apply the available updates.

Canadian Centre for Cyber Security · 12d agoAdvisory

[Control systems] Schneider Electric security advisory (AV26-871)

Canada's Cyber Centre relayed Schneider Electric advisories for vulnerabilities in NetBotz 5-750/755 (5.5.2 and prior) and PowerChute Serial Shutdown (1.5 and prior).

The Canadian Centre for Cyber Security issued control-systems advisory AV26-871 noting Schneider Electric products affected by vulnerabilities as of September 1, 2026. Affected products include NetBotz 5-750/755 versions 5.5.2 and prior, and PowerChute Serial Shutdown versions 1.5 and prior, the latter with an improper restriction of excessive authentication attempts flaw. Administrators are urged to review Schneider Electric's security notifications and apply the suggested mitigations and updates.

Canadian Centre for Cyber Security · 14d agoAdvisory

[Control Systems] Siemens security advisory (AV26-864)

Siemens fixed a vulnerability in Element maps-ng V47-V49 (SSA-682041); Canada's Cyber Centre urges administrators to apply the updated releases.

Siemens advisory SSA-682041 addresses a vulnerability affecting Element maps-ng V47 prior to V47.12.3, V48 prior to V48.11.3, and V49 prior to V49.16.1. Canada's Cyber Centre republished the notice (AV26-864) encouraging users and administrators to review the vendor links and apply the necessary updates. No CVSS score or exploitation details were provided in the bulletin.

Canadian Centre for Cyber Security · 15d agoAdvisory

[Control Systems] National Instruments security advisory (AV26-856)

Canada's Cyber Centre relayed National Instruments advisories for memory corruption, out-of-bounds read, and out-of-bounds write flaws in LabVIEW versions.

The Canadian Centre for Cyber Security published control systems advisory AV26-856 covering National Instruments LabVIEW. Affected versions include releases before 23.0.0, 23.3.10, 24.3.7, 25.3.5, and 26.3.1. The flaws include memory corruption, an integer conversion out-of-bounds read, and an integer overflow out-of-bounds write. Users and administrators are urged to review the links and apply NI security updates.

Canadian Centre for Cyber Security · 19d agoAdvisory

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

Poster: Towards Selecting Threat Appropriate Industrial Intrusion Detection Systems

Poster proposes counter-threat-intelligence-based detector selection for industrial control systems, showing IDS performance varies strongly by attack scenario.

The poster proposes a counter-threat intelligence sharing mechanism to select appropriate intrusion detection systems for the current threat situation in industrial control system environments. Attack-level performance evaluations of various IDSs show detection performance varies depending on the attack scenario. The results emphasize the benefit of dynamically matching detectors to evolving ICS threats.

arXiv cs.CR · 5d agoResearch

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

CISA Advisoriesupdated · 4d agofirst · 6d agoAdvisory 2 sourcesCVE-2026-82583CVE-2026-78224CVE-2026-82578

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 13d agoAdvisoryCVE-2026-77393

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

Threat landscape for industrial automation systems. Q2 2026

Kaspersky's Q2 2026 report tracks ransomware, miners, and spyware detected on industrial control systems worldwide.

Kaspersky Securelist published statistics on threats blocked on industrial automation systems during Q2 2026. The report covers ransomware, cryptocurrency miners, spyware, and other malware detected on ICS environments. The quarterly telemetry gives OT defenders a view of threat trends affecting industrial infrastructure.

Kaspersky Securelist · 20d agoResearch

ZDI-26-648: (Pwn2Own) OpenAI Codex External Control of System or Configuration Setting Remote Code Execution Vulnerability

ZDI published a Pwn2Own advisory for CVE-2026-19590, enabling remote code execution in OpenAI's Codex agent via system or configuration control.

Zero Day Initiative advisory ZDI-26-648 documents an External Control of System or Configuration Setting vulnerability in OpenAI Codex, demonstrated at Pwn2Own. A remote attacker could achieve arbitrary code execution, with user interaction required such as opening malicious content. The flaw is tracked as CVE-2026-19590 with a CVSS rating of 7.8. No exploitation in the wild is reported.

Security through obscurity is dead, and AI delivered the fatal blow

AI agents are killing security through obscurity, accelerating vulnerability discovery and patch-gap exploitation, experts warn, with OT/ICS systems most at risk.

An opinion/analysis piece arguing AI has made security through obscurity obsolete, citing record vulnerability disclosure volumes after Microsoft's Patch Tuesday addressed 974 CVEs. FBI Cyber Division assistant director Brett Leatherman said latest AI models found significant vulnerabilities in open source libraries running on most web servers. The article cites at least four espionage crews (most suspected China-linked) exploiting Chromium's patch-gap window with a rapid exploit kit, and a five-agency advisory on AI-generated exploitation scripts breaching internet-exposed Siemens S7 Series PLCs at water, manufacturing, and energy facilities. Experts including John Hultquist, Chris Inglis, and Katie Moussouris warn AI erodes the expertise barrier protecting obscure OT/ICS systems while defensive AI patching lags, with studies showing AI-generated patches fail more than half the time.

The Register · Security · 3d agoIndustry

Multiple Vulnerabilities Discovered in a SCADA System

Unit 42 details five vulnerabilities (CVSS 7.0-7.8) in ICONICS Suite SCADA software enabling privilege escalation and DoS.

Unit 42 discovered five vulnerabilities (CVE-2024-1182, CVE-2024-7587, CVE-2024-8299, CVE-2024-8300, CVE-2024-9852) in ICONICS Suite versions 10.97.2 and earlier for Windows during a 2024 security assessment. The flaws, rated CVSS 7.0-7.8, allow DLL hijacking, privilege escalation, information disclosure, denial-of-service and potentially full system compromise. ICONICS Suite is a SCADA solution with hundreds of thousands of installations in over 100 countries, widely used in critical infrastructure, and several dozen servers are internet-exposed per Unit 42 telemetry. ICONICS released patches and advisories with workarounds in 2024.

Trump Targets Foreign Technology in New U.S. Power Grid Security Order

Trump's Executive Order 14420 declares a national emergency to restrict foreign-made bulk-power grid equipment over cyber, sabotage and supply-chain risks.

Executive Order 14420, signed August 26, declares a national emergency regarding the foreign supply of bulk-power system electric equipment to the United States. It empowers the Energy Secretary to restrict transactions with designated Covered Foreign Entities involving equipment, software, firmware, digital services, maintenance services, and remote-access capabilities. Covered equipment includes transformers, generators, inverters, RTUs, PLCs, intelligent electronic devices, and protective relays, with transmission rated 69 kV or higher in scope while local distribution is excluded. Already-installed foreign equipment may be subject to identification, isolation, monitoring, or replacement requirements, with phased compliance and pre-qualified vendor exemptions permitted.

Security Affairs · 18d agoPolicy & legal

CVE-2026-86206, CVE-2026-86207: N-able N-central Authentication Bypass (FIXED)

Rapid7 disclosed two chained N-able N-central flaws, CVE-2026-86206 and CVE-2026-86207, enabling unauthenticated admin account creation; patched in 2026.3 Hotfix 3.

Rapid7 researchers found CVE-2026-86206 (semicolon/Forwarded access-control bypass, CWE-791, CVSSv4 6.9) and CVE-2026-86207 (UserTwoFactorLogin authentication bypass, CWE-305, CVSSv4 7.7) in the latest N-able N-central. Chained, they let a remote unauthenticated attacker create an attacker-controlled System administrator account. The bugs stem from Envoy and Jetty disagreeing on the requested path and whether the client is local. N-able patched both in N-central 2026.3 Hotfix 3, following the earlier CVE-2026-18577 authentication bypass.

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 13d agoAdvisoryCVE-2026-77477

Your AI agent's system prompt is not a security control

AWS and SANS guidance says system prompts are not security controls; enforce user permissions at retrieval time and default-deny every agent tool invocation.

AWS VP Gee Rittenhouse and SANS fellow Eric Johnson, with three AWS security specialists, published agentic AI security guidance for organizations with agents running or under development. They recommend scoping queries to user permissions inside existing RBAC/ABAC systems and filtering results before the model's context window, noting prompts can be bypassed, ignored, or overridden. The guidance warns risk concentrates when one agent holds sensitive data access, external communication, and exposure to untrusted content, the vector for prompt injection, which OWASP ranks as the top AI application threat. It cites IBM 2025 research that ungoverned shadow AI added $670,000 to average breach cost, and prescribes 30-day behavioral baselines, Cedar or Open Policy Agent for default-deny tool invocation, and four-layer containment with automatic circuit breakers.

Help Net Security · 9d agoAI safety & security

You don’t have to join the hack-back program to inherit its risk

A new US presidential memorandum creates a vetted private hack-back program, leaving participating vendors and their customers with untested legal liability and collateral risks.

The August 12 National Security Presidential Memorandum directs the National Coordination Center, run jointly by DOJ and DHS, to approve covert surveillance and disruptive Cyber Effects Operations by vetted private companies, with a forfeitable bond of at least $1 million required as a contract condition. The analysis argues the criminal shield rests on an untested reading of the CFAA exemption at 18 U.S.C. 1030(f), with no civil safe harbor, no state-law preemption and no foreign-law protection. Non-participating organizations can still inherit risk through shared infrastructure collateral damage, lack of customer disclosure, Lloyd's bulletin Y5381 state-backed attack exclusions, and threat-intelligence pipelines feeding offensive proposals.

CSO Online · 4h agoPolicy & legal