CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

AI-Generated Exploit Scripts Target Siemens S7 PLCs in U.S. Critical Infrastructure

NSA, CISA, FBI, DOE and EPA warn that actors use AI-generated Python scripts to exploit internet-exposed Siemens S7 PLCs at U.S. critical infrastructure.

A joint advisory from NSA, CISA, FBI, DOE and EPA describes an active threat in which AI-generated exploit scripts disguised as legitimate monitoring tools target Siemens S7 Series PLCs (S7-200 through S7-1500, including F-series safety controllers). The actors use Censys and ZoomEye scanning to find internet-exposed, outdated PLCs and a custom Python script using snap7 libraries over the S7comm protocol for initial access, credential access and denial of service; no attribution was given. Targeted sectors include Critical Manufacturing, Energy, Water and Wastewater, Chemical, Food and Agriculture, and Commercial Facilities, with potential for process disruption and cascading impacts. A related Dream report details a near-autonomous AI-agent campaign (July 1-4, 2026, 12 waves) against Taiwan government entities, using Hermes and OpenClaw agents with eight parallel sub-agents to crack 85 accounts via password spraying and exfiltrate over 2,564 personnel records, SSO client secrets and database credentials.

The Hacker News · 26d agoExploit / PoC in the wild1

NSA, CISA, FBI, DOE, and EPA Warn of Active AI

Five US agencies warn of active AI-assisted attacks on internet-exposed Siemens S7 PLCs across critical infrastructure, using disguised snap7 scripts for pre-positioning reconnaissance.

NSA, CISA, FBI, DOE, and EPA issued joint advisory CISA AA26-231A warning of an active hacking campaign against Siemens S7-series PLCs, from S7-200 through S7-1500 F-series, across US critical infrastructure. Threat actors use internet scanning services such as Censys and ZoomEye to locate exposed controllers, then perform read operations over S7comm on TCP port 102 using the legitimate snap7.dll and python-snap7 libraries, disguising AI-generated exploitation scripts as monitoring tools. The agencies assess the activity as pre-positioning ahead of possible process disruption, equipment damage, or safety incidents in Energy, Water, Critical Manufacturing, Chemical, Food and Agriculture, and Commercial Facilities sectors.

Security Affairs · 27d agoExploit / PoC in the wild

Florida water agency latest to confirm cyber incident as feds warn of nation

A ransomware gang hit Florida's St. Johns River Water Management District as CISA warned of IRGC-linked CyberAv3ngers attacks on exposed Unitronics water-sector PLCs.

The St. Johns River Water Management District, which oversees Florida drinking-water supply planning, confirmed suspicious activity in its IT environment and said containment measures were implemented; a ransomware gang claimed the attack and shared samples of stolen data. Separately, CISA, FBI, NSA, EPA and Israel's INCD warned that IRGC-affiliated CyberAv3ngers are actively compromising Israeli-made Unitronics Vision Series PLCs in the water sector using default credentials since at least November 22. The group, motivated by opposition to Israel-linked products, defaces controller interfaces and could cause deeper cyber-physical effects. Shadowserver found at least 539 Unitronics PLC instances still exposed online, and CNN reported fewer than 10 US water facilities faced recent attacks.

The Record · 9d agoRansomware in the wild 3 sources

CISA Warns Water Utilities: Find Your Exposed PLCs Before Attackers Do

CISA urged water utilities to secure internet-exposed PLCs after July 2026 attacks compromised over 100 US water and wastewater systems, suspected Iran-linked.

CISA's exposure-reduction guidance, published August 21, follows July 2026 attacks in which threat actors remotely accessed PLCs connected directly through cellular modems, changed device IP addresses and passwords, and in some cases disabled alarms and shutdown processes without notifying operators. Iran is the suspected actor, though officials stopped short of formal attribution. CISA recommends routing remote access through centrally managed secure gateways, phishing-resistant MFA, unique credentials, and external scanning of industrial protocols such as Modbus, EtherNet/IP, DNP3, BACnet and OPC UA.