ZeroHour

Search: “Organization B”

855 stories

CISA Red Team Fully Compromised Two Critical Infrastructure Orgs

CISA red teams achieved full domain and cloud compromise at two critical infrastructure orgs; one SOC never detected the intrusion.

CISA advisory AA26-237A documents two simultaneous red team assessments. Organization A (Government Services sector) missed the intrusion entirely, as default credentials on a web app, ADCS ESC1 abuse, and thousands of false-positive alerts let the red team reach sensitive business systems and read SOC email. Organization B (Water/Wastewater sector) detected, isolated, and reimaged hosts quickly, but both orgs lacked Conditional Access for workload identities, and B still exposed DCSync, Golden Ticket, and OT network attack paths.

Security Affairs · 20d agoAdvisory1

Water sector passes, government sector fails attempts to spot and halt simulated CISA attack

CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.

CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.

CyberScoop · 21d agoAdvisory1

CISA Red Team Compromised Two Critical Infrastructure Orgs, One Detected Nothing

CISA red teams fully compromised two critical infrastructure orgs with similar tradecraft; one detected nothing, the other contained phishing within minutes.

CISA advisory AA26-237A, 'A Tale of Two SOCs,' describes two simultaneous red team assessments of a Government Services organization and a Water and Wastewater Systems organization, both compromised to the domain level. Organization A never detected the intrusion, enabled by default credentials, a misconfigured AD CS template (ESC1), cleartext credentials, non-expiring static AWS keys, and over-permissioned Entra ID applications. Organization B detected and isolated phishing within 2-20 minutes, though the red team still reached krbtgt via DCSync from cleartext SCCM credentials. CISA attributes the outcome gap to people and processes rather than the security tools themselves.

The Hacker News · 20d agoAdvisory

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 16h agoAdvisoryCVE-2026-80465

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 16h agoAdvisoryCVE-2026-81861

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 16h agoAdvisoryCVE-2026-58113

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 12d agoAdvisoryCVE-2026-4827

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.