CVE-2026-24858
KEVmassFortiCloud SSO Authentication Bypass Across Multiple Fortinet Products
CISA: Fortinet Multiple Products Authentication Bypass Using an Alternate Path or Channel Vulnerability
CVE-2026-24858 is an authentication bypass (CWE-288) in FortiCloud single sign-on that lets an attacker who owns a FortiCloud account with any registered device log in to other customers' Fortinet devices that have FortiCloud SSO authentication enabled. It affects a wide range of 7.x/8.x builds of FortiOS, FortiProxy, FortiWeb, FortiAnalyzer, FortiManager, FortiNAC-F, and the Siemens RUGGEDCOM APE 1808. An attacker gains unauthorized access to devices registered to other accounts, and related reporting describes FortiGate devices being exploited to breach networks and steal service account credentials. Any organization running an affected build with FortiCloud SSO enabled is exposed. Exploitation is confirmed in the wild: CISA added the flaw to the KEV catalog on 2026-01-27 and Fortinet patched it after active FortiOS SSO exploitation was detected, and EPSS assigns an 86.1% probability of exploitation within 30 days.
What to do: Upgrade all affected Fortinet products to the fixed releases specified in Fortinet's PSIRT advisory for CVE-2026-24858; as an interim mitigation, disable FortiCloud SSO authentication on affected devices and audit which devices are registered to your FortiCloud account. Review device logs for unexpected administrative logins or signs of service-account credential theft on FortiGate, and federal agencies must apply mitigations per BOD 22-01 (including CISA's cloud services guidance) or discontinue use of the product.
| Fortinet FortiAnalyzer | 7.6.0-7.6.5, 7.4.0-7.4.9, 7.2.0-7.2.11, 7.0.0-7.0.15 |
| Fortinet FortiManager | 7.6.0-7.6.5, 7.4.0-7.4.9, 7.2.0-7.2.11, 7.0.0-7.0.15 |
| Fortinet FortiNAC-F | 7.6.3-7.6.5 |
| Fortinet FortiOS | 7.6.0-7.6.5, 7.4.0-7.4.10, 7.2.0-7.2.12, 7.0.0-7.0.18 |
| Fortinet FortiProxy | 7.6.0-7.6.4, 7.4.0-7.4.12, 7.2.0-7.2.15, 7.0.0-7.0.22 |
| Fortinet FortiWeb | 8.0.0-8.0.3, 7.6.0-7.6.6, 7.4.0-7.4.11 |
| Siemens RUGGEDCOM APE 1808 firmware | — |
Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.
An Authentication Bypass Using an Alternate Path or Channel vulnerability [CWE-288] vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.5, FortiAnalyzer 7.4.0 through 7.4.9, FortiAnalyzer 7.2.0 through 7.2.11, FortiAnalyzer 7.0.0 through 7.0.15, FortiManager 7.6.0 through 7.6.5, FortiManager 7.4.0 through 7.4.9, FortiManager 7.2.0 through 7.2.11, FortiManager 7.0.0 through 7.0.15, FortiNAC-F 7.6.3 through 7.6.5, FortiOS 7.6.0 through 7.6.5, FortiOS 7.4.0 through 7.4.10, FortiOS 7.2.0 through 7.2.12, FortiOS 7.0.0 through 7.0.18, FortiProxy 7.6.0 through 7.6.4, FortiProxy 7.4.0 through 7.4.12, FortiProxy 7.2.0 through 7.2.15, FortiProxy 7.0.0 through 7.0.22, FortiWeb 8.0.0 through 8.0.3, FortiWeb 7.6.0 through 7.6.6, FortiWeb 7.4.0 through 7.4.11 may allow an attacker with a FortiCloud account and a registered device to log into other devices registered to other accounts, if FortiCloud SSO authentication is enabled on those devices.
- Affected
- Fortinet Multiple Products
- Required action
- Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
- Due date
- Ransomware use
- Unknown