Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

Cisco Identity Services Engine Authenticated Remote Code Execution and API Vulnerabilities

Cisco fixed ISE vulnerabilities enabling authenticated SQL injection and OS command execution; CVE-2026-20282 and CVE-2026-20283 rated High.

Multiple Cisco Identity Services Engine vulnerabilities allow an authenticated remote attacker to conduct SQL injection, modify data, or execute arbitrary commands on the underlying OS. Cisco assigned a Security Impact Rating of High to CVE-2026-20282 and CVE-2026-20283 because attackers can easily reach root from the achieved privilege level. Software updates are available and a workaround addresses one of the vulnerabilities.

Cisco Security Advisoriesupdated · 40m agofirst · 19h agoAdvisory 21 sourcesCVE-2026-20282CVE-2026-20283

Oracle Critical Security Patch Update, September 2026 Review

Oracle's September 2026 Critical Patch Update fixes 673 vulnerabilities, including 104 critical, with many remotely exploitable in E-Business Suite and Fusion Middleware.

Oracle released 673 security patches in its September 2026 Critical Patch Update: 104 rated critical, 503 high, and 59 medium. Oracle E-Business Suite received the most patches (159, 24% of total), with 19 exploitable without credentials including CVE-2026-83327, CVE-2026-83452, and CVE-2026-83462 at CVSS 9.8. Fusion Middleware received 153 patches with 78 remotely exploitable without authentication, and 41 patches address third-party open-source component flaws. Qualys published detection QIDs for vulnerable assets.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 13d agoAdvisoryCVE-2026-77477

Rockwell Automation ArmorStart LT

CISA flags two flaws (CVE-2026-19471, CVE-2026-19472) in Rockwell Automation ArmorStart LT <=v2.001: stored XSS and web server denial-of-service.

Rockwell Automation reported two issues in the embedded web server of ArmorStart LT v2.001 and earlier. CVE-2026-19471 involves multiple stored cross-site scripting flaws (CVSS 7.3) where unsanitized input is stored server-side and executes in other users' browsers. CVE-2026-19472 is a denial-of-service issue (CVSS 7.5) triggered by a crafted HTTP PUT request that exhausts web server resources. No public exploitation has been reported to CISA.

Water sector passes, government sector fails attempts to spot and halt simulated CISA attack

CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.

CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.

CyberScoop · 22d agoAdvisory1

Cisco Advance Notification for Publication of August 19, 2026, Security Advisories

Cisco PSIRT's advance notice previews August 19, 2026 advisories including Critical CVSS 10.0 hardening releases for Crosswork and Secure Workload.

Cisco PSIRT issued an advance notification for security advisories published August 19, 2026. The batch includes Critical-rated (CVSS 10.0) hardening releases for Cisco Crosswork and Cisco Secure Workload, a High-severity blind XML External Entity injection in BroadWorks (CVE-2026-20320, CVSS 7.5), a Medium SQL injection in Unified Intelligence Center (CVE-2026-20327, CVSS 6.5), and a RoomOS stack overflow. Full details and fixes follow in the individual advisories.