Schneider Electric SCADAPack x70 Products
CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.
CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.
AVEVA Pipeline Integrity Monitor
CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.
CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.
NextGen Healthcare Mirth Connect
CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.
CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.
Orthanc DICOM Server
CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.
CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.
Inductive Automation Ignition
CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.
CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.
Tycon Systems TPDIN-Monitor-WEB3
CISA reports three flaws (hard-coded credentials, CSRF, missing authorization) in Tycon TPDIN-Monitor-WEB3 <=2.2.9 enabling MitM, credential theft, or device resets.
CISA published ICSA-26-246-08 for Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior, covering CVE-2026-77847 (use of hard-coded credentials, CWE-798), CVE-2026-82712 (CSRF, CWE-352), and CVE-2026-82684 (missing authorization, CWE-862). Exploitation could enable man-in-the-middle attacks, factory resets, credential wiping, or extraction of system credentials, configurations, and flash contents; the CSRF issue scores CVSS 8.8. No public exploitation has been reported; CISA recommends isolating devices from business networks.
Siemens Teamcenter
Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).
CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.
Rockwell Automation 1756-ENBT Module
Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.
CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.
[Control Systems] Inductive Automation security advisory (AV26-892)
Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.
The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.
China-Based Artificial Intelligence Companies Conducting Industrial-Scale Distillation Campaigns Against U.S. AI Companies
NSA, CISA, and FBI warn DeepSeek, Alibaba, and other Chinese AI firms ran industrial-scale distillation of U.S. frontier models, threatening U.S. AI leadership.
A joint NSA, CISA, and FBI Cybersecurity Advisory (AA26-251A) says China-based firms DeepSeek, Moonshot AI, Alibaba, MiniMax, StepFun, and Z.AI extracted billions of tokens from U.S. frontier models including Claude, GPT, Gemini, and Grok, likely with Chinese government knowledge. Campaigns running since at least late 2024 used native APIs, cloud providers, third-party aggregators, gray-market proxy "transfer stations", and shared premium subscriptions to bypass geographic restrictions, evade safeguards, and violate providers' terms of use. The agencies recommend detecting anomalous prompts, accounts, and usage patterns; subtly altering responses to suspected distillers; and cross-organization intelligence sharing. They also call DeepSeek's publicly cited $5.6M training cost misleading because it excludes data acquired through distillation.
Rockwell Automation Historian ME
CISA warns CVE-2025-12768 and CVE-2026-12661 in Rockwell Historian ME could crash devices or allow remote code execution via out-of-bounds writes; CVSS 8.
CISA issued an ICS advisory for Rockwell Automation Historian ME Series B 5.202 and Series C 7.101. CVE-2025-12768 and CVE-2026-12661 involve out-of-bounds write and stack-based buffer overflow flaws that could crash the accessed device or enable remote code execution. The product is deployed across chemical, critical manufacturing, healthcare, and water and wastewater sectors worldwide.
Rockwell Automation Logix Platform
CISA warns Rockwell Automation Logix controllers (ControlLogix, CompactLogix, GuardLogix) up to V36.012 are affected by CVE-2026-9637 (CVSS 7.5).
CISA published ICS advisory ICSA-26-244-03 covering the Rockwell Automation Logix Platform. Affected products include ControlLogix 5580, CompactLogix 5380, GuardLogix 5580, and Compact GuardLogix 5380 running firmware through V33 and selected V34-V36 releases. The underlying vulnerability is tracked as CVE-2026-9637 with a vendor CVSS v3 score of 7.5. The advisory provides guidance for industrial operators to update affected controllers.
Rockwell Automation FactoryTalk Activation Manager
CISA details CVE-2026-16675, a CVSS 7.8 privilege escalation flaw in Rockwell FactoryTalk Activation Manager V5.02 and below, with vendor fixes available.
CISA issued an ICS advisory for Rockwell Automation FactoryTalk Activation Manager. CVE-2026-16675 is a privilege escalation vulnerability stemming from installer custom actions, scored 7.8. Versions V5.02 and below are affected, and Rockwell Automation has released fixes.
Rockwell Automation Redundancy Module Configuration Tool
CISA warns CVE-2026-9633 in Rockwell Automation Redundancy Module Configuration Tool lets attackers execute processes with administrator privileges; fix in 10.01.00.
CISA released an ICS advisory for Rockwell Automation Redundancy Module Configuration Tool. CVE-2026-9633 could allow an attacker to escalate privileges and execute processes with administrator rights. Versions 9.00.00 through 10.00.00 are affected, and the vendor shipped a fix in version 10.01.00.
Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix
CISA advisory maps CVE-2021-42260 to Rockwell ControlLogix, CompactLogix, and GuardLogix controllers with firmware below per-series patch levels.
CISA published an ICS advisory associating CVE-2021-42260 with multiple Rockwell Automation controller families: ControlLogix 5580, GuardLogix 5580, CompactLogix 5380, CompactLogix 5480, and Compact GuardLogix 5380. Affected firmware versions fall below 34.015, 35.014, 36.013, and 37.011 depending on the series. The vendor provides updated firmware as remediation.
Rockwell Automation RSLinx Classic
CISA flags four flaws (CVE-2026-9621/9622/9624/9625) in Rockwell RSLinx Classic 4.50 and below that can cause denial-of-service conditions; CVSS 8.6.
CISA published an ICS advisory covering four vulnerabilities in Rockwell Automation RSLinx Classic versions 4.50 and below. The integer overflow, underflow, and classic buffer overflow flaws (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) could let attackers cause denial-of-service conditions. The product is deployed worldwide, primarily in critical manufacturing.
All-Line Equipment Company Fuel-Boss
CISA warns All-Line Equipment Fuel-Boss product versions contain flaws enabling remote command or code execution; fixes are available for some variants only.
CISA published ICS advisory ICSA-26-239-02 covering vulnerabilities in All-Line Equipment Company Fuel-Boss products, including the V1 Standard, V1 Portal, V1 Master/Slave, and V1 Backflush. Successful exploitation could allow attackers to execute arbitrary commands or code remotely on affected systems. Vendor fixes are available for Fuel-Boss V1 Standard and V1 Portal, fixes are not yet available for V1 Master/Slave, and no fix is planned for V1 Backflush. Customers are directed to contact All-Line Equipment Company for remediation instructions.
Ebyte NA111-M
CISA reports 13 vulnerabilities, including CVSS 9.8 missing-authentication flaws, in Ebyte NA111-M firmware that allow full device compromise.
CISA published ICS advisory ICSA-26-239-05 for Ebyte NA111-M firmware 9013-2-17, listing 13 vulnerabilities tracked from CVE-2026-73125 through CVE-2026-77977. The issues include missing authentication for critical functions, GET requests with sensitive query strings, cross-site request forgery, improper restriction of excessive authentication attempts, and missing authorization. The vendor-assessed CVSS v3 score is 9.8, and successful exploitation could allow an attacker to fully compromise the device. No remediation details are included in the summary text.
September 2026 Patch Tuesday forecast: All we need is more time
September 2026 Patch Tuesday forecast expects record CVE volume after August's 398 fixes, with SharePoint flaws CVE-2026-55040 and CVE-2026-63520 actively exploited.
This Patch Tuesday forecast column notes August 2026 Patch Tuesday was the second largest ever with 398 resolved CVEs, yet only one was confirmed actively exploited. SharePoint flaws CVE-2026-55040 and CVE-2026-63520 are being chained for authentication bypass and remote code execution in active attacks against unpatched servers. Microsoft Defender's ShieldBreak elevation of privilege flaw (CVE-2026-69414) is publicly disclosed with PoC code and a fix is expected, while Chrome CVE-2026-85046 was reported exploited in the wild. Several products, including Windows 11 24H2 Home/Pro and Exchange Server 2016/2019 ESU, reach end of support in October 2026.