Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

[Control Systems] National Instruments security advisory (AV26-914)

Canada's Cyber Centre relayed a National Instruments advisory covering improper access control and cleartext sensitive-information flaws in NI SystemLink and SystemLink Server.

Advisory AV26-914, dated September 11, 2026, notes that NI SystemLink and SystemLink Server prior to or equal to 2026 Q3 Patch 1 are affected by improper access controls and storage of sensitive information in cleartext. The Canadian Centre for Cyber Security urges users and administrators to review the vendor's links and apply available security updates.

Canadian Centre for Cyber Security · 5d agoAdvisory2

[Control Systems] Siemens security advisory (AV26-890)

Canada's Cyber Centre relayed a Siemens advisory affecting Reyrolle 7SR5, Teamcenter, Siveillance Control, Desigo CC and other products.

Advisory AV26-890, dated September 8, 2026, flags Siemens vulnerabilities in Reyrolle 7SR5 (versions prior to V2.70), Teamcenter, Siveillance Control, SIMATIC AX Runtime, Desigo CC, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT across multiple versions and models. The Cyber Centre encourages users and administrators to review the Siemens advisory and apply available updates. No specific CVEs or exploitation details are provided in the relayed advisory.

Canadian Centre for Cyber Security · 8d agoAdvisory

[Control Systems] Phoenix Contact security advisory (AV26-927)

Canadian Cyber Centre warns Phoenix Contact, Pepperl+Fuchs, and Carlo Gavazzi I/O devices need firmware 1.7.4 to fix multiple vulnerabilities.

Canada's Cyber Centre issued advisory AV26-927 covering multiple vulnerabilities in Phoenix Contact ICE2/ICE3 and IOL MA8 EIP/PN devices, plus related Pepperl+Fuchs and Carlo Gavazzi YL212/YN115 products. Firmware versions prior to 1.7.4 are affected across roughly 15 models. Administrators are encouraged to review vendor advisories and apply available updates.

[Control systems] GeoVision security advisory (AV26-913)

Canada's Cyber Centre (AV26-913) warns GeoVision GV-LPC2011/LPC2211 firmware 1.13 license-plate cameras are affected by vulnerabilities and urges updates.

The Canadian Centre for Cyber Security issued control-systems advisory AV26-913 on September 11, 2026, noting that GeoVision GV-LPC2011/LPC2211 firmware version 1.13 is affected by vulnerabilities. The bulletin references the vendor advisory GV-LPC-2026-09-01 but provides no CVE identifiers or exploitation details. Administrators are encouraged to review the linked advisories and apply updates as they become available.

Canadian Centre for Cyber Security · 5d agoAdvisory

[Control systems] Schneider Electric security advisory (AV26-912)

Canada's Cyber Centre relays a Schneider Electric advisory covering multiple vulnerabilities in EcoStruxure IT Data Center Expert and PowerLogic T300, urging users to apply updates.

The Canadian Centre for Cyber Security issued advisory AV26-912 noting that as of September 9, 2026 Schneider Electric is affected by vulnerabilities in EcoStruxure IT Data Center Expert versions 9.1.2 and prior, and PowerLogic T300 versions 2.9.8-5620 and prior. The issues include an improper neutralization of special elements used in an OS command on the PowerLogic T300. The advisory recommends reviewing vendor notifications, performing suggested mitigations, and applying necessary updates.

Canadian Centre for Cyber Security · 5d agoAdvisory

[Control systems] Advantech security advisory (AV26-907)

Canada's Cyber Centre flagged vulnerabilities in the Advantech WISE-6610 industrial gateway and urged users to apply available updates.

Advisory AV26-907, dated September 10, 2026, states that multiple versions and models of the Advantech WISE-6610 industrial gateway are affected by vulnerabilities. The Canadian Centre for Cyber Security encourages users and administrators to review the provided links and apply updates as they become available. No CVE identifiers or exploitation details were included in the announcement.

Canadian Centre for Cyber Security · 6d agoAdvisory

[Control Systems] Inductive Automation security advisory (AV26-892)

Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.

The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.

Canadian Centre for Cyber Security · 8d agoAdvisory

[Control Systems] Siemens security advisory (AV26-881)

Siemens patched an account hijacking vulnerability in the Mendix SAML module affecting Mendix 9.24, 10, and 11 releases before fixed versions.

The Canadian Centre for Cyber Security relayed Siemens advisory SSA-887643, which addresses an account hijacking vulnerability in the Mendix SAML module. Affected components are the Mendix 10 and Mendix 11 compatible modules prior to V4.2.3 and the Mendix 9.24 compatible module prior to V3.6.27. Administrators are encouraged to review the linked advisories and apply the available updates.

Canadian Centre for Cyber Security · 13d agoAdvisory

[Control systems] Schneider Electric security advisory (AV26-871)

Canada's Cyber Centre relayed Schneider Electric advisories for vulnerabilities in NetBotz 5-750/755 (5.5.2 and prior) and PowerChute Serial Shutdown (1.5 and prior).

The Canadian Centre for Cyber Security issued control-systems advisory AV26-871 noting Schneider Electric products affected by vulnerabilities as of September 1, 2026. Affected products include NetBotz 5-750/755 versions 5.5.2 and prior, and PowerChute Serial Shutdown versions 1.5 and prior, the latter with an improper restriction of excessive authentication attempts flaw. Administrators are urged to review Schneider Electric's security notifications and apply the suggested mitigations and updates.

Canadian Centre for Cyber Security · 14d agoAdvisory

[Control Systems] Siemens security advisory (AV26-864)

Siemens fixed a vulnerability in Element maps-ng V47-V49 (SSA-682041); Canada's Cyber Centre urges administrators to apply the updated releases.

Siemens advisory SSA-682041 addresses a vulnerability affecting Element maps-ng V47 prior to V47.12.3, V48 prior to V48.11.3, and V49 prior to V49.16.1. Canada's Cyber Centre republished the notice (AV26-864) encouraging users and administrators to review the vendor links and apply the necessary updates. No CVSS score or exploitation details were provided in the bulletin.

Canadian Centre for Cyber Security · 16d agoAdvisory

[Control Systems] National Instruments security advisory (AV26-856)

Canada's Cyber Centre relayed National Instruments advisories for memory corruption, out-of-bounds read, and out-of-bounds write flaws in LabVIEW versions.

The Canadian Centre for Cyber Security published control systems advisory AV26-856 covering National Instruments LabVIEW. Affected versions include releases before 23.0.0, 23.3.10, 24.3.7, 25.3.5, and 26.3.1. The flaws include memory corruption, an integer conversion out-of-bounds read, and an integer overflow out-of-bounds write. Users and administrators are urged to review the links and apply NI security updates.

Canadian Centre for Cyber Security · 19d agoAdvisory

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

CISA Advisoriesupdated · 5d agofirst · 6d agoAdvisory 2 sourcesCVE-2026-82583CVE-2026-78224CVE-2026-82578

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 13d agoAdvisoryCVE-2026-77393

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113