ZeroHour

Search: “cwe”

416 stories

[0day-rubbish] Royal Server 5.04.50529.0 Local privilege escalation to LocalSystem on the execution path without credential override (7.2)

0day Rubbish Research Team disclosed a CVSS 7.2 local privilege escalation (CWE-250) in Royal Server 5.04.50529.0 to LocalSystem.

Researchers publicly disclosed a local privilege escalation vulnerability in Royal Server 5.04.50529.0, classified as CWE-250 (execution with unnecessary privileges) with a CVSS score of 7.2. The flaw allows escalation to LocalSystem on the execution path without credential override. The disclosure was posted to the Full Disclosure mailing list on September 8, 2026; no patch or CVE id was mentioned in the notice.

Full Disclosure · 8d agoVulnerability

[0day-rubbish] SmarterMail 100.0.9693 (Build 9693) Antivirus command-line configuration executing as NT AUTHORITY\SYSTEM (7.2)

SmarterMail 100.0.9693 executes its antivirus command-line configuration as NT AUTHORITY\SYSTEM, a CWE-250 flaw rated CVSS 7.2.

0day Rubbish Research Team disclosed that SmarterMail 100.0.9693 (build 9693) runs its antivirus command-line configuration with NT AUTHORITY\SYSTEM privileges, classified as CWE-250 (deployment of executable with unnecessary privileges) and rated CVSS 7.2. Control over that configuration could yield SYSTEM-level code execution on the mail server. The disclosure does not report exploitation in the wild.

Full Disclosure · 8d agoVulnerability

CVE-2026-86206, CVE-2026-86207: N-able N-central Authentication Bypass (FIXED)

Rapid7 disclosed two chained N-able N-central flaws, CVE-2026-86206 and CVE-2026-86207, enabling unauthenticated admin account creation; patched in 2026.3 Hotfix 3.

Rapid7 researchers found CVE-2026-86206 (semicolon/Forwarded access-control bypass, CWE-791, CVSSv4 6.9) and CVE-2026-86207 (UserTwoFactorLogin authentication bypass, CWE-305, CVSSv4 7.7) in the latest N-able N-central. Chained, they let a remote unauthenticated attacker create an attacker-controlled System administrator account. The bugs stem from Envoy and Jetty disagreeing on the requested path and whether the client is local. N-able patched both in N-central 2026.3 Hotfix 3, following the earlier CVE-2026-18577 authentication bypass.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

NASA AIT-GUI Flaws Could Let Unauthenticated Attackers Issue Spacecraft Commands

Researchers disclosed 9.4-CVSS flaws in NASA/JPL's AIT-GUI allowing unauthenticated attackers to issue arbitrary spacecraft commands via exposed command endpoints.

Cycode disclosed a flaw chain in AIT-GUI, the browser-based operator console for NASA/JPL's open-source AMMOS Instrument Toolkit, tracked as GHSA-p9r8-2q67-fp86 with CVSS 9.4, affecting versions 2.5.1 and earlier. The server binds to 0.0.0.0:8080, issues sessions without credential checks, and lets unauthenticated users issue spacecraft commands via POST /cmd and reach files outside intended directories via /script/run and /seq (CWE-306, CWE-352, CWE-22). Version 2.5.2 adds host binding and same-origin checks but does not add authentication, and a related missing-authentication flaw was published separately as CVE-2026-60112 with CVSS 9.3.

The Hacker News · 27d agoVulnerabilityCVE-2026-601121

Unisoc VoLTE Video Call Exploit Chain Can Give Attackers Full Android Kernel Access

Unisoc modem firmware flaw CWE-1189 allows VoLTE video call RCE chain to gain full Android kernel access on T606/T612/T7250 chipsets; no patch yet.

SSD Secure Disclosure published the second stage of an exploit chain, first disclosed in March 2026, that achieves full Android kernel access on Unisoc modem firmware via a VoLTE video call. The privilege-escalation flaw, classified as CWE-1189 (Improper Isolation of Shared Resources on System-on-a-Chip), exploits shared physical memory between modem and application processor with no hardware boundary, letting modem code map the entire 32-bit address space and modify Android kernel pages via ARM Memory Protection Unit registers. Confirmed affected chipsets include Unisoc T606 (Motorola E13), T612 (Realme C33), and T7250 (Xiaomi Redmi A5), sold across more than 140 countries. No CVE has been assigned, the August 2026 Android Security Bulletin does not address it, and Unisoc has not responded to researchers; exploitation requires an attacker-controlled private 4G network and a victim answering the call.

CISA Warns of Critical ScreenConnect Vulnerability Actively Exploited in Attacks

CISA added actively exploited ConnectWise ScreenConnect flaw CVE-2026-84869 to the KEV catalog, setting a September 14 patch deadline.

CISA added CVE-2026-84869, a critical improper privilege management and missing authorization flaw (CWE-269, CWE-862) in ConnectWise ScreenConnect, to its Known Exploited Vulnerabilities Catalog on September 11, 2026, confirming active exploitation. The flaw lets attackers transfer files to a device and execute them during an active remote ScreenConnect session without authorization or host-user confirmation, enabling payload delivery, unauthorized tools, and persistence while blending into legitimate remote-management traffic. CISA set a September 14 remediation deadline under BOD 26-04 and flagged the vulnerability as requiring forensic triage. ConnectWise has published a security bulletin, and defenders are urged to review exposure, sessions, file-transfer records, and outbound connections.

Cyber Security News · 11h agoExploit / PoC in the wild 4 sourcesCVE-2026-848691

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

Vulnerability Localization Benchmark: Measuring Agentic Security Analysis at Repository Scale

VLoc Bench tests 27 language models at locating vulnerable files in 290 repositories; best system reaches 0.229 File F1 and 38.4% of tasks unsolved.

The Vulnerability Localization Benchmark (VLoc Bench) contains 500 real-world vulnerabilities from 290 repositories across six package ecosystems and 147 CWE categories, pairing pre-fix and post-fix repository snapshots. Agents receive only a CWE description and read-only terminal access to identify affected files, and must confirm absence on patched snapshots. The strongest of 27 language models and four static-analysis tools achieves just 0.229 File F1; 38.4% of tasks receive no correct localization, and effective localizers still report unsupported locations on patched repositories.

arXiv cs.AI / cs.LG / cs.CL · 2d agoAI research

CVE-2026-85706: Critical GitLab Path Traversal Exploited in the Wild

CVE-2026-85706, a CVSS 10.0 unauthenticated path traversal in GitLab CE/EE, is actively exploited and was added to CISA's KEV catalog.

GitLab patched CVE-2026-85706, a critical path traversal (CWE-22) in the repository commits API scoring CVSSv3.1 10.0, allowing unauthenticated arbitrary file reads on affected self-managed servers under certain conditions. CISA added it to the KEV catalog on September 11, 2026, citing active exploitation, with a September 14 remediation deadline and BOD 26-04 forensic triage requirements. Fixed versions are 19.1.8, 19.2.6, and 19.3.2; the release also fixes 17 other vulnerabilities including CVE-2026-87719, a CVSS 9.9 insecure deserialization flaw in GitLab EE.

Rapid7 Blogupdated · 2d agofirst · 2d agoExploit / PoC in the wild 18 sourcesCVE-2026-85706CVE-2026-877192

CISA Adds Exploited MikroTik RouterOS Flaws to Security Alert

CISA added two actively exploited MikroTik RouterOS flaws, CVE-2026-67277 and CVE-2026-86060, to its KEV catalog with a September 13 mitigation deadline.

CISA added CVE-2026-67277 and CVE-2026-86060 in MikroTik RouterOS to the Known Exploited Vulnerabilities catalog on September 10, giving federal agencies until September 13 to apply vendor mitigations. CVE-2026-67277 is a missing-authentication flaw (CWE-306) in the bandwidth-test (btest) service that can expose kernel memory and cause denial of service; CVE-2026-86060 (CWE-88) lets attackers manipulate the trusted RouterOS policy mask for privilege escalation. CISA designated CVE-2026-86060 as requiring forensic triage under Binding Operational Directive 26-04, meaning organizations should hunt for compromise indicators, not just patch. Compromised routers could have altered routing rules, persistence, traffic interception, or use as pivots into internal networks.

GBHackers · 5d agoExploit / PoC in the wild 2 sourcesCVE-2026-67277CVE-2026-860601

Critical Check Point VPN Vulnerabilities Enable Remote Code Execution Attacks

Check Point patched two critical VPN flaws, CVE-2026-85102 and CVE-2026-85103 (CVSS 9.8), allowing unauthenticated RCE on Security Gateways.

Check Point disclosed and patched two critical VPN vulnerabilities, CVE-2026-85102 (improper certificate trust validation, CWE-295) and CVE-2026-85103 (heap-based buffer overflow in ASN.1 certificate parsing, CWE-122), both rated CVSS 9.8 and exploitable for unauthenticated remote code execution under specific conditions. The flaws affect Security Gateway, Security Management Server, and Spark Firewall deployments on R81.20, R82, and R82.10 branches plus end-of-support versions such as R80.40 and R81, while R82.20 is not affected. Check Point reports no evidence of active exploitation or public PoC; Live Patch rollout began September 9, 2026, and administrators without it must install Jumbo Hotfix Accumulator builds (R82.10 Take 44+, R82 Take 126+, R81.20 Take 166+). For Site-to-Site VPN, restricting UDP ports 500 and 4500 to known peers serves as an interim workaround, but no mitigation exists for Remote Access VPN or Spark Firewalls.

Cyber Security Newsupdated · 9h agofirst · 6d agoVulnerability 9 sourcesCVE-2026-85102CVE-2026-85103CVE-2026-50751

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

CISA Warns of Fortinet Heap-based Buffer Overflow Flaw Exploited in Attacks

CISA added actively exploited Fortinet CVE-2025-25249, a critical heap-based buffer overflow in FortiOS, FortiSwitchManager, and FortiSASE, to its KEV catalog.

CVE-2025-25249 is a heap-based buffer overflow (CWE-122/CWE-787) allowing unauthorized code execution by sending specially crafted packets. CISA added it to the Known Exploited Vulnerabilities catalog on September 9, 2026, with a September 12 remediation deadline for federal agencies under BOD 26-04 and mandatory forensic triage of affected environments. Internet-facing Fortinet firewalls and SASE platforms are a likely foothold for credential theft, persistence, and lateral movement; ransomware use is currently listed as unknown.

Cyber Security Newsupdated · 6d agofirst · 6d agoExploit / PoC in the wild 6 sourcesCVE-2025-252492

CVE-2026-37171: SuperTokens Core cross-tenant session isolation bypass (6.0.0-11.4.0)

CVE-2026-37171: SuperTokens Core 6.0.0-11.4.0 lacks tenant separation in session operations, enabling cross-tenant access.

CVE-2026-37171 (CWE-863, Incorrect Authorization) affects SuperTokens Core, the self-hosted authentication server by SuperTokens Inc., versions 6.0.0 through 11.4.0. The Core lacks tenant separation in session operations, permitting cross-tenant authorization bypass. The CVE is published, with advisory entries NVD and GitHub GHSA-j7vw-hh5c-2w6x; the disclosure does not mention any observed exploitation.

oss-security · 7d agoVulnerabilityCVE-2026-371711

FortiSandbox Vulnerability Allows Attackers to Access Sensitive Information via Crafted HTTP Requests

Fortinet disclosed CVE-2026-26084 (CVSS 8.9), an unauthenticated information-disclosure flaw in the FortiSandbox web UI, urging upgrades.

Fortinet patched CVE-2026-26084, a CWE-284 improper access control flaw in the shared web UI of FortiSandbox, FortiSandbox Cloud, and FortiSandbox PaaS that lets unauthenticated attackers read sensitive data via crafted HTTP requests. Affected releases include FortiSandbox 5.0.0-5.0.5 and 4.4.0-4.4.8, Cloud 5.0.4-5.0.5, and PaaS 5.0.4-5.0.5; fixes arrive in 5.0.6+ and 4.4.9+, while FortiSandbox 5.2 and Cloud 4.4 are unaffected. The issue was found internally by Fortinet's Product Security team, and the company reports no evidence of exploitation in the wild. Disclosure carries only confidentiality impact, but exposed sandbox configurations and logs could aid follow-on attacks.

CVE-2026-34908: UniFi OS Auth Bypass Vulnerability

Ubiquiti disclosed CVE-2026-34908, a CVSS 10.0 authentication bypass in UniFi OS letting network-adjacent attackers alter device configuration without credentials.

CVE-2026-34908 is an improper access control flaw (CWE-284) in Ubiquiti UniFi OS devices, disclosed in UI Security Advisory Bulletin 064, with a CVSS 3.1 base score of 10.0. An unauthenticated network-adjacent attacker can bypass access controls and modify system configuration, with scope-changed impact on downstream network services such as routing, VPN, and connected access points. Fixed firmware is available, and workarounds include restricting management ports to trusted subnets, isolating management interfaces on a dedicated VLAN, and disabling remote access features. No public proof-of-concept code was observed at the time of publication.

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

CVE-2026-34908: Ubiquiti Networks UniFi OS Server access control ...

CVE-2026-34908, a CVSS 10.0 access-control bypass in Ubiquiti UniFi OS, was added to CISA's KEV catalog amid reported active exploitation.

CISA added CVE-2026-34908 to the Known Exploited Vulnerabilities catalog on June 23, 2026, with remediation due June 26 under BOD 26-04 guidance. The CVSS 10.0 improper access control flaw (CWE-284) in Ubiquiti UniFi OS allows unauthorized system changes without authentication. Multiple news reports referenced by the page describe the max-severity UniFi flaws being exploited in attacks, and an official patch is available.

CVE-2026-50522: Microsoft SharePoint Server RCE Vulnerability

CVE-2026-50522 is an unauthenticated .NET deserialization RCE in SharePoint Server Subscription, 2019, and 2016; Microsoft patched it July 14, 2026.

CVE-2026-50522 (CWE-502) lets unauthenticated attackers send crafted serialized .NET payloads to network-accessible SharePoint endpoints, triggering gadget-chain deserialization and remote code execution under the privileged SharePoint service account. It affects SharePoint Server Subscription Edition, SharePoint Server 2019, and SharePoint Server 2016 Enterprise; Microsoft published the advisory on July 14, 2026. The EPSS score is 20.346%, but no public PoC exists and the flaw is not in CISA's KEV catalog at publication. Mitigations include applying Microsoft updates, rotating SharePoint machine keys, enabling AMSI, and restricting internet exposure.

CVE-2026-16232: Checkpoint Quantum Security Management auth bypass ...

Attackers exploit Check Point SmartConsole authentication bypass CVE-2026-16232 to take over Quantum Security Management firewall servers; CISA added it to KEV.

CVE-2026-16232 is an authentication bypass (CWE-287) in the SmartConsole login process of Check Point Quantum Security Management, exploitable via an application token. Disclosed July 22, 2026, it was added to CISA's Known Exploited Vulnerabilities catalog the same day with remediation due July 25. Rapid7, Check Point Research and other vendors confirmed exploitation in the wild, and a public PoC was released. A workaround is available, and federal agencies must comply with BOD 26-04 patching guidance.

AL26-019 - Vulnerabilities impacting Citrix NetScaler ADC and NetScaler Gateway - CVE-2026-19490 and CVE-2026-19489

Canadian Cyber Centre alerts on Citrix NetScaler ADC/Gateway flaws CVE-2026-19490 (authentication bypass) and CVE-2026-19489 (buffer overflow), urging emergency patching.

The Canadian Centre for Cyber Security issued alert AL26-019 covering two Citrix NetScaler vulnerabilities disclosed in a vendor advisory on August 19, 2026. CVE-2026-19490 (CWE-288) allows a remote unauthenticated attacker to bypass authentication on appliances configured as a Gateway for SSL VPN, ICA Proxy, CVPN, RDP Proxy, or as an AAA virtual server. CVE-2026-19489 (CWE-120) is a classic buffer overflow that may cause memory overflow, unpredictable behavior, or denial-of-service conditions. Affected appliances are vulnerable when configured as a SAML IdP; fixed versions include 14.1-73.32, 13.1-63.21, and 13.1-37.277 for FIPS.

The History Is the Detector: Executing CVE Patch History, End-to-End

BUGSTONE-E2E converts CVE patch history into executable LLM-guided detection rules, yielding 1,033 rules and 644 runtime-verified findings across 14 programs.

The BUGSTONE-E2E framework mines reusable detection rules from verified fixing commits, organized by CWE and language, and applies them through a funnel pipeline that escalates from Tree-sitter anchors and lightweight heuristics to LLM-based agent inspection, runtime verification, and scope-checked patch generation. Built from 19,325 high-severity CVEs published 2022-2026, it produced 1,033 detection rules spanning 56 CWE families, packaged into 172 skills. Applied across 14 programs, it generated runtime evidence for 644 findings, demonstrating that vulnerability history can drive reproducible detection and repair.

arXiv cs.CR · 12d agoResearch

CVE-2026-16232: Check Point SmartConsole Auth Bypass

Check Point SmartConsole authentication bypass CVE-2026-16232 grants unauthenticated attackers full admin access; actively exploited and added to CISA KEV.

CVE-2026-16232 is an improper authentication flaw (CWE-287) in the Check Point SmartConsole login process that lets an unauthenticated remote attacker obtain an application token and authenticate with full administrative privileges. Exploitation requires the Management Server to be internet-reachable and the Trusted Clients list not restricted to specific administrator addresses. Check Point confirmed active exploitation affecting a small number of customers, and the vulnerability has been added to the CISA Known Exploited Vulnerabilities catalog. A hotfix is available via Check Point advisory sk185169.