CISA warns of unpatched critical flaw in Danfoss AK-SM controllers

Original title: CISA warns of critical unpatched flaw in Danfoss refrigeration controllers

BleepingComputerby Bill Toulas ()2 min read3 · 1 read
Part of a story covered by 6 sourcesUnpatched Danfoss AK-SM 8xxA flaw can run code without loginMerged summary & timeline
AI summary · x-ai/grok-4.7Summaries by Vani AI

CVE-2026-129713, scored 9.8, is an unauthenticated stack overflow; Danfoss says a fix is coming in 5.5.x and none is out.

CISA warned of a critical stack-based buffer overflow in Danfoss AK-SM 8xxA Series refrigeration, HVAC, and lighting controllers used by food retailers. CVE-2026-129713, scored 9.8, can be triggered without authentication to restart the server and potentially run code as the web server. Danfoss said on November 20 that version 5.5.x will fix it and remove the option to turn off Strict mode, but no patch is available. Recent European supermarket incidents remotely changed or shut down cooling; a supplier said attackers reused the same vulnerability seen in France in October.

Unconfirmed: Sabcobel said the November attacks reused the October vulnerability; the text does not quote CISA confirming CVE-2026-129713 was exploited.

Key facts
  • The AK-SM 800A line includes the 820A, 850A, and 880A models.
  • CISA says the controllers are deployed worldwide; the installed base is unknown.
  • October 11–12 attacks in France were attributed to IRGC-linked Shahid Kaveh.
  • On November 2, at least 115 stores in seven European countries were affected.
  • A French blood-service refrigeration supplier had cold-storage settings changed at three sites.
Security assessment · AI, from the articleExploited in the wild

Impact: Unauthenticated remote code execution as the web server

ProductAffectedFixed in
Danfoss AK-SM 8xxA Series—5.5.x
What to do
  1. 1.Keep controllers off the public internet and minimize network exposure.
  2. 2.Segregate control systems from business networks and place them behind firewalls.
  3. 3.Use up-to-date VPNs when remote access is required.
Analyze CVE-2026-129713 with Vani AIImpact, affected versions, exploitation, mitigations and detection

Vulnerabilities mentioned

All
CVEVulnerabilityCVSSEPSSSignalsPublished
CVE-2026-129713
Unauthenticated stack overflow in Danfoss AK-SM 8xxA CGI
9.3—

From the original article

2 min read at bleepingcomputer.com

The U. S. Cybersecurity and Infrastructure Security Agency (CISA) is warning about a critical vulnerability in Danfoss AK-SM 8xxA Series controllers used by food retailers to manage commercial refrigeration, HVAC, and lighting systems.

BleepingComputer

By Bill Toulas · bleepingcomputer.com

Read the full article at BleepingComputer

A short excerpt; the article and its images belong to the publisher. Summary, key facts and assessment above are AI-written from the article and can be wrong.