Unpatched Danfoss AK-SM 8xxA flaw can run code without login

4 sources · 6 articlesFirst reported Updated ()1
What's new

November 26: Cyber Security News names ICSA-26-328-03 and DSA-2026-12-01 and says Danfoss recommends Strict Mode until 5.5.x.

Merged summary · x-ai/grok-4.7 · rewritten as coverage arrivesSummaries by Vani AI

CVE-2026-129713 remains unpatched in Danfoss AK-SM 8xxA controllers; a 5.5.x fix is planned and CISA reports no known exploitation.

CISA says an unauthenticated stack-based buffer overflow in a CGI handler affects Danfoss AK-SM 8xxA refrigeration, HVAC, and lighting controllers through version 5.4.0. CVE-2026-129713, CVSS v3.1 9.8 and CVSS v4.0 9.3, can be triggered by crafted HTTP or HTTPS POST requests, restarting the web server and potentially executing code with webserver privileges. Danfoss said on November 20 that software 5.5.x will fix the flaw and later remove the option to turn off Strict mode; no patch is available, and Danfoss recommends Strict Mode until then. CISA reports no known public exploitation. BleepingComputer says a supplier linked recent European supermarket cooling attacks to the same vulnerability, a link CISA has not confirmed.

Key facts
  • CVE-2026-129713 affects AK-SM 8xxA controllers through version 5.4.0, including 820A, 850A, and 880A.
  • No login is required; a password alone does not mitigate the flaw.
  • Danfoss plans a fix in 5.5.x; none is available yet.
  • Carlo Meijer of Midnight Blue reported the issue to CISA.
  • CISA published advisory ICSA-26-328-03; Danfoss advisory is DSA-2026-12-01.
Analyze this story with Vani AIImpact, who is affected and what defenders should do, in a new chat

Timeline

dated events in the reporting · oldest first
  1. Nov 20, 2026Danfoss says 5.5.x will fix the flaw · BleepingComputer
  2. Nov 24, 2026CISA publishes advisory ICSA-26-328-03 · Cyber Security News

What each outlet adds

beyond the shared facts
  • CISA AdvisoriesCVSS v4.0 9.3 and CGI handler detail
  • BleepingComputerController models and unconfirmed supermarket-attack link
  • Cyber Security NewsAdvisory IDs and interim Strict Mode advice

Coverage

oldest first · one row per article · UTC
  1. · 1d ago CISA AdvisoriesFirst report

    Unauthenticated overflow in Danfoss AK-SM 8xxA, no patch yet

    CVE-2026-129713 scores CVSS 9.8; Danfoss says a fix is planned in version 5.5.x, and CISA knows of no exploitation.

  2. · 1d ago CISA Known Exploited Vulnerabilities

    CISA KEV lists Danfoss AK-SM path traversal CVE-2023-25914

    An attacker can read underlying server system files through the XML interface; agencies face a November 28, 2026 due date.

  3. · 1d ago CISA Known Exploited Vulnerabilities

    CISA KEV adds Danfoss AK-SM 800A auth flaw CVE-2025-41450

    Attackers can generate a web report exposing internal IP addresses, usernames, and store names; the federal due date is December 9, 2026.

  4. · 1d ago CISA Known Exploited Vulnerabilities

    CISA KEV adds Danfoss AK-SM command flaw CVE-2023-25915

    A remote attacker can run arbitrary commands on affected AK-SM 800A systems; the BOD 26-04 due date is November 28, 2026.

  5. · 17h ago BleepingComputer

    CISA warns of unpatched critical flaw in Danfoss AK-SM controllers

    CVE-2026-129713, scored 9.8, is an unauthenticated stack overflow; Danfoss says a fix is coming in 5.5.x and none is out.

  6. · 1h ago Cyber Security News

    Danfoss AK-SM 8xxA flaw allows unauthenticated remote code execution

    CISA rates CVE-2026-129713 at 9.8 and reports no known exploitation; Danfoss plans a fix in 5.5.x.

Vulnerabilities in this story

All
CVEVulnerabilityCVSSEPSSSignalsPublished
CVE-2023-25915
+1 related CVE
Authenticated command execution in Danfoss AK-SM 800A
8.81%KEV
KEV
CVE-2025-41450
Improper authentication in Danfoss AK-SM 800A before 4.2
7.5<1%KEVPoC ×2
KEV
CVE-2026-129713
Unauthenticated stack overflow in Danfoss AK-SM 8xxA CGI
9.3—