ZeroHour

Search: “vpn”

68 stories

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

Cisco Secure Firewall Adaptive Security Appliance and Secure Firewall Threat Defense Software SSL VPN Denial of Service Vulnerability

Cisco expanded an SSL VPN denial-of-service advisory to cover all ASA and FTD software platforms; unauthenticated attackers can exhaust device memory.

A vulnerability in the VPN and management web servers of Cisco ASA Software and Cisco Secure FTD Software allows an unauthenticated remote attacker to exhaust system memory or buffer blocks, causing a denial of service. Originally scoped to the ASAv and FTDv virtual appliances, Cisco updated the advisory on September 16, 2026 to cover all ASA and FTD platforms.

Cisco Security Advisories · 13h agoAdvisory 9 sources

Cisco Secure Firewall Adaptive Security Appliance and Secure Firewall Threat Defense Software Remote Access SSL VPN Denial of Service Vulnerability

Cisco patched an unauthenticated remote DoS in ASA and FTD Remote Access SSL VPN that reloads devices via crafted HTTP requests.

Cisco disclosed a denial-of-service vulnerability in the Remote Access SSL VPN service of Secure Firewall ASA and FTD software. Insufficient error checking when processing HTTP requests allows an unauthenticated, remote attacker to send a crafted HTTP request that causes the affected device to reload. Cisco has released software updates addressing the flaw.

Cisco Security Advisories · Aug 11, 2026Advisory

Check Point security advisory (AV26-902)

Canada's Cyber Centre issued advisory AV26-902 warning of two Check Point RCE flaws, including VPN authentication bypass CVE-2026-85102.

The Canadian Centre for Cyber Security released advisory AV26-902 on September 9, 2026, covering vulnerabilities in Check Point Security Gateway, Spark Firewall with Site-to-Site or Remote Access VPN, and Security Management Server across multiple versions. CVE-2026-85102 is an authentication bypass and remote code execution flaw in Remote Access and Site-to-Site VPN, while CVE-2026-85103 is an ASN.1 decoding heap overflow enabling remote code execution. Administrators are urged to review the linked advisories and apply updates as they become available.

AL26-019 - Vulnerabilities impacting Citrix NetScaler ADC and NetScaler Gateway - CVE-2026-19490 and CVE-2026-19489

Canadian Cyber Centre alerts on Citrix NetScaler ADC/Gateway flaws CVE-2026-19490 (authentication bypass) and CVE-2026-19489 (buffer overflow), urging emergency patching.

The Canadian Centre for Cyber Security issued alert AL26-019 covering two Citrix NetScaler vulnerabilities disclosed in a vendor advisory on August 19, 2026. CVE-2026-19490 (CWE-288) allows a remote unauthenticated attacker to bypass authentication on appliances configured as a Gateway for SSL VPN, ICA Proxy, CVPN, RDP Proxy, or as an AAA virtual server. CVE-2026-19489 (CWE-120) is a classic buffer overflow that may cause memory overflow, unpredictable behavior, or denial-of-service conditions. Affected appliances are vulnerable when configured as a SAML IdP; fixed versions include 14.1-73.32, 13.1-63.21, and 13.1-37.277 for FIPS.

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

CISA promotes a fresh way to deter cyberattackers: Lie to them

CISA issued first-time guidance advising critical infrastructure operators to deploy honeypots, honeytokens, and decoys to detect and distract intruders.

CISA published 'Using Cyber Decoys to Strengthen Detection and Response,' a 22-page guide marking the agency's first guidance on decoys such as honeypots and honeytokens. Acting executive director Chris Butera described decoys as a low-cost, high-fidelity way to detect adversaries already inside networks, complementing zero-trust and assume-compromise approaches. The guidance covers decoy principles, definitions, deployment scenarios, and is aimed especially at resource-constrained critical infrastructure sectors.

CyberScoop · 9h agoAdvisory

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

Best Practices for Good Endpoint Hardening | Huntress

Huntress outlines endpoint hardening best practices, citing exposed RDP, RMM tool abuse, and ClickFix social engineering as common SMB intrusion paths.

Huntress published defensive guidance on endpoint hardening for small and mid-sized businesses, drawing on observations from its SOC. The post describes common intrusion vectors: internet-exposed RDP brute-forced by automated scanners, phishing emails delivering attacker-controlled remote monitoring and management (RMM) tools, with Huntress reporting a 277% spike in RMM abuse in 2025, and ClickFix attacks using fake CAPTCHA pages that trick users into running malicious commands. Recommended controls include scanning for exposed RDP, SSH, and VPN interfaces, removing unneeded local admin rights, enabling Windows Defender tamper protection, disabling SMBv1, and standardizing on one approved remote access tool, guided by CIS and NIST frameworks.

Huntress · 6d agoAdvisory

Orthanc DICOM Server

CISA advisory flags CVE-2026-87020, an integer overflow in Orthanc DICOM Server <1.13.0 causing heap out-of-bounds write and denial of service when decoding crafted PNG/JPEG images.

CISA published ICSMA-26-253-02 for Orthanc DICOM Server versions below 1.13.0, used in healthcare environments worldwide. CVE-2026-87020 (CWE-190) is an integer overflow in pitch and buffer-size computation causing a heap out-of-bounds write when decoding attacker-supplied PNG or JPEG images. An authenticated remote attacker can crash the Orthanc process and cause denial of service; CVSS v3.1 is 8.1 HIGH. CISA states no known public exploitation targeting this flaw has been reported.

CISA Advisories · 6d agoAdvisoryCVE-2026-87020

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

NextGen Healthcare Mirth Connect

CISA warns NextGen Healthcare Mirth Connect <=4.7.1 has SQL injection and XXE flaws enabling credential theft, file writes, and DoS.

CISA released advisory ICSMA-26-253-01 covering three vulnerabilities in NextGen Healthcare Mirth Connect versions 4.7.1 and earlier: SQL injection CVE-2026-82583 (CVSS 8.3), XXE CVE-2026-78224 (CVSS 8.2), and XXE CVE-2026-82578 (CVSS 7.5). Exploitation could expose stored credentials for connected systems, enable arbitrary file writes, and cause denial-of-service conditions. No public exploitation has been reported; the product is deployed worldwide in the Healthcare and Public Health sector.

CISA Advisoriesupdated · 5d agofirst · 6d agoAdvisory 2 sourcesCVE-2026-82583CVE-2026-78224CVE-2026-82578

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

Rockwell Automation 1756-ENBT Module

Rockwell's 1756-ENBT ControlLogix EtherNet/IP bridge (all versions) is vulnerable to DoS via crafted CIP packets, crashing the module until manual restart.

CISA republished Rockwell Automation's advisory for CVE-2025-10478, a CWE-754 flaw affecting all versions of the 1756-ENBT ControlLogix EtherNet/IP bridge, scored CVSS 7.5. A crafted CIP packet can crash the module, and the device requires a restart to recover. Affected critical infrastructure sectors include critical manufacturing, food and agriculture, transportation systems, and water. No public exploitation has been reported; CISA recommends minimizing network exposure.

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 13d agoAdvisoryCVE-2026-77393

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

Water sector passes, government sector fails attempts to spot and halt simulated CISA attack

CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.

CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.

CyberScoop · 22d agoAdvisory1

AI-fueled attacks pose ‘active threat’ to water, other sectors, U.S. agencies warn

NSA, CISA, FBI, DOE and EPA warn hackers are using AI-generated scripts to actively attack Siemens S7 PLCs across critical-infrastructure sectors.

A joint cybersecurity advisory from the NSA, CISA, FBI, Department of Energy and EPA warns of an active threat campaign targeting water, food, energy, chemical, manufacturing and commercial facilities via Siemens S7 Series programmable logic controllers. The actors use internet scanning to find exposed or poorly protected PLCs, then deploy AI-generated exploitation scripts disguised as legitimate monitoring tools, an OT first that dramatically lowers the expertise required for ICS attacks. Siemens says no new S7 vulnerabilities are involved, only exploitation of misconfigurations, and it is coordinating with CISA's ProductCERT. The warning follows a joint FBI-EPA advisory confirming attacks at water and wastewater utilities in at least 12 states since July 27.

CyberScoop · 27d agoAdvisory in the wild1